My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4933 GLENWOOD AVE 2016-01-01 MF Import
>
Address Records
>
GLENWOOD AVE
>
4933
>
4933 GLENWOOD AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2017 7:58:33 AM
Creation date
2/14/2017 7:58:12 AM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
4933
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Jordan Construction � JN 00284 <br /> July 25, 2000 Page 4 <br /> overexcavation and ttie footing width. For example, an overexcavation extending 2 feet below the <br /> bottom of a 2-foot-wide footing must be at least 4 feet wide at the base of the excavation. If lean <br /> concrete is used, the overexcavation need only extend 6 inches beyond the edges of the footing. <br /> An allowable bearing pressure of 2,000 pounds per sauare foot (ps� is appropriate for footings <br /> supported on competent, native soil, imported structural fill, or lean mix concrete. A one-third <br /> increase in this design bearing pressure may be used when considering short-term wind or seismic <br /> loads. For the above design criteria, it is anticipated that the total post-construction settlement of <br /> footings founded on competent, native soil, or on structural fili up to 5 feet in thickness, will be <br /> about one-half inch, with differentiai settlements on the order of ona inch in a distance of 50 feet <br /> along a continuous footing with a uniform load. <br /> Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and <br /> the bearing soil, or by passive earth pressura acting on the vertical, embedded portions of the <br /> foundation. For the latter condition, the foundation must be either poured directly against relatively <br /> level, undisturbed soil or be surrounded by level structural fill. We recommend using the following <br /> design values for the foundation's resistance to lateral loading: <br /> Coefficient of Friction 0.40 <br /> Passive EartY. Pressure 350 pcf <br /> Where:(I)pct Is pountls per cublc toot,�ntl(il)passlve earth <br /> pressure is computed using the equivatent fluid density. <br /> If the ground in front of a foundation is loose or slopir,g, the passive earth pressure given above will <br /> not be appropriate. We recommend a safety fuctor of at least 1.5 for the foundation's resistance to <br /> lateral loading, when using the above design values. <br /> SEISMIC CONS/DERATIONS <br /> The site is locateci within Seismic Zone 3, as illustrated on Figure No. 16-2 of the 1997 Uniform <br /> Building Code (UEC). In accordance with Table 16-J of the 1997 UBC, the site soil profile is best <br /> represented by Soil Profile Type S� (Very Dense Soil). The site soils are not subject to seismic <br /> liquefaction because of their dense nature and the absence of near-surface groundwater. <br /> SLABS-ON-GRADE <br /> The building floors may be constructed as slabs-on-grade atop medium-dense, weathered, gravelly <br /> sand overlying the dense till. The concrete slab couid be piaced on the existing fill if steps are <br /> taken to till up the existing fill soils, re-roll, and compact them according to the <br /> recommendations discussed later in the GENERAL EARTHWORK AND STRUCTURAL FILL <br /> section of this report. The subgrade soil must be in a firm, non-yielding condition at the time of sl�b <br /> construction or underslab fill placement. Any soft areas encountered should be excavated and <br /> replaced wth select, imported structural fill. <br /> �,� r <br /> � <br /> GEOTECH CONSULTANTS,INC. <br /> S <br />
The URL can be used to link to this page
Your browser does not support the video tag.