prior to installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Building Department electrical permil must be presc <br /> for any installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Building Department. <br /> Elec��«31 inspections and approval are required prior to calling (or acceptance tests. Call (425) 257- <br /> 8810 for permit information. <br /> 10. Commercial Cookinq Operations - A ventilating hood and duct system with an approved automatic <br /> fire-extinguishing syslem shall be provided in accordance with the DAechanical Code for commercial- <br /> type food heat-processing �quipment that produces grease-laden vapors. <br /> 11. Kitchens - Install a K-type fire extinguisher within 30 feet of the grill and deep fryers. <br /> 12. Fire Suppression (Sprinkler) System -An approved automalic suppression system shall be provided <br /> as required by City Ordinance No. 1902-92, Chapter 16.76, of the Everelt Municipal Code. The <br /> system must include a mechanicai water gong bell. <br /> Plans for any such system shall be submitted to lhe Building Department fur examination and <br /> approval. Such plans sha!I include plans for the underground mains that will supply ihe sprinkler <br /> system. <br /> The type of sprinkler to be installed will be determined by the Buiiding Official. It may be an NFPA <br /> 13, NFPA 13R, or NFPA 13D system depending upon several factors. Sprink�er installation shall not <br /> begin without an approved and stamped set of plans from the Building Department. The Fire <br /> Department will also review the plans and shall field inspect the installation based only on approved <br /> plans that must be on site. Changes to plans must be approved by both the Building and Fire <br /> Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br /> for private fire mains. Delow-qround pipinq must be installed bV Washinqton State Patrol <br /> Licensed Undernround Sprinkler line certified "U" installers. For further information, contact <br /> the State Fire Marshal's Office at (3S0) 570-3134 or contact the Everett Fire Department at <br /> (425) 257-8123. All such tests shall be witnessed by a Fire Department inspector. Call (425) ?57- <br /> 8123 to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br /> issuance of any Certificates of Occupancy. <br /> Call (425) 257-8123 for more information. <br /> f 13. The old tanks shall be pumped out with fuel properly disposed of prior to removal. No product or <br /> II <br /> rinse water may be disposed of in such a way that it could enter the storm drains system. <br /> 14. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets with <br /> standard man door access. Locations shall be approved by the Fire Marshal's Office. <br /> 15. Trash Collection - Dumpsters over 1.5 cubic yards capacity shall be located a minimum of 5 feet <br /> irom the building [IFC 304.3.3, 2003 Edition]. <br /> �; : <br />