Laserfiche WebLink
Iy <br /> R.e.PAIR S?E�_FICaTZONS AND LIST OF :QORt. TO BE BID <br /> Page 6 of 13 <br /> Address : 3406 Lombard <br /> Install two new 200 amp electric breaker service nanels <br /> in basemeut to replace existing, on separate meters, <br /> including weathercap, service entrance cable , meter <br /> base, grounding, and panelboards with breakers. Square <br /> D or equal. Separate circuits serving each unit, <br /> running new circuits as necessary. Public area <br /> electrical wiring . divided between the two panels . <br /> Label all circuits . <br /> Install new doorbells at front door including buttons , <br /> wiLing, transformers and bells for each unit, Nutone or <br /> equal. <br /> Install new battery operated smoke detectors , one in <br /> hall outside downstairs bedtooms, and two upstairs , <br /> outside each bedroom. <br /> Install new range hood in upstaits kitcheri, minumum 200 <br /> CFM delivery, Nutone or equal, vented out through roof. <br /> Install exhaust fans in upstairs and downstairs <br /> bathtooms, minimum 80 CFM air delivery, Nutone or equal, <br /> vented out house, controlled on same switch as main <br /> bathroom light fixture. <br /> Install new recessed electric resistance heaters with <br /> fans, Cadet Register Series or equal, as follows : one <br /> in each bedroom in the house (4) , one in each kitchen <br /> (2) , and one in each living/dining area (2) . Size _ <br /> heaters to each room and locate on interior walls when <br /> possible. Install wa11 mounted thermostats ;above each <br /> heater. <br /> Install ceiling mounted infrared lamp heaters in �aci� <br /> bath=oom, controlled with new wall switches. Furnish <br /> infrared bulbs. <br /> Install new duplex receptacle: as follows: G.F.I. ' s in <br /> the upstairs and downstaits bathroom, two in the east <br /> bedroom downstaits , two in the east bedroom upstairs , <br /> two .in the south bedroom upstairs, two in the living <br /> room upstairs and two in the kitchen upstairs. Multiple <br /> receptacles in any room : installed on different walls , <br /> owner choice of locations. <br /> Install new electric light fixtures, on new switches <br /> unless existing, as follows: one on the downstairs <br /> living room ceiling, one on the downstairs dining room <br /> ceiling, two on the downstairs kitchen ceiling, one on <br /> the ceiling of the hail outside the downstairs bedrooms , <br /> one on the ceiling of the west bedroom downstairs , one <br /> each on the front and back porches, one each on the <br /> ceilings of the upstaics bedrooms, one on the ceiling of <br /> the upstairs kitchen, one on the ceiling of the upstairs <br /> living roomn, one on the ceiling oE' the upstairs <br /> bathroom, one on the ceiling of the hall adjacent to the <br /> upstairs entry door, and one in the stairwell to the <br /> upstairs apartment (on a 3-way switch) . Allowance per <br /> fixture : $Z5. <br /> $ : 9�" <br />