Laserfiche WebLink
July 20, 1993 <br />UBL.L I�YOl�KS <br />Reykdal Construction <br />1810 Chestnut Street <br />Everett, Washington 98201 <br />RE: Owner: Bill Berg <br />Job Address: 3605 I.ombard <br />Plan Check No.: 41166 <br />�ear Mr. Berg: <br />In response to your applicaGon for a construction permit, your plans have been <br />examined and you are adv�sed that the issuance of a permit is being withheld for the <br />reasons listed below. These comments address building issues only, additional <br />revisions or additions may be required by other departments (such as Udlit�es, Planning <br />StaFe f Wash'mgton and/oreWash ngton StatelEnergyUCode 1991e 2nd Editi n�, unless <br />stated otherwise. <br />1. Exterior walls shall have fire resistanr.e and opening protection as set forth in <br />Table No. 5-A, part III• Table 5-A requires walls less than 3 feet from the <br />property line to be one-hour fire-resistive construc6on and dces not permit any <br />openmgs in exterior walls less than 3'-0" from the property line. These rules <br />apply to all new construction. <br />2. 8' pls hall be designedb b al l censedl W sh ngtona State Swct ual Engeineer�. <br />Submit design and details. <br />3. Plans do not show size, species, grade or spacing of framing members in <br />cripple wall. Show sheathing, studs, moisture barrier and siding. If the space <br />is heated, it is required to be msulated. <br />4. Show the height of the storage space from the top of the slab-on-grade to the <br />bottom of the floor�oists. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 ''�s,�'- <br />