Laserfiche WebLink
a� <br />Y:. <br />• <br />74(IM/O WOM LF <br />Royale Homes <br />Plan Check #50675 <br />February 7, 1996 <br />Page 2 of 4 <br />5. Call out size of hip beam at front porch. <br />6. Provide double joists at each end of both cantilevers, show on foundation plan. <br />7. Show blocking at ends of rafters and trusses w exterior walls and at supports of floor <br />joists/2326.8.3. <br />8. Delete notes and details that do not apply to t his project. <br />9. Show how dwelling is provided with comfort heating facilities capable of maintaining a <br />room temperature of 70°F (21' c) at a point 3' (914mm) above the floor in all habitable <br />rooms./310.11 UBC. <br />10. Provide continuous handrail per section 1006.9 UBC. Show on plan view and in stair <br />section. <br />11. Provide detail of attic ventilation type, size and location. Show the required net area <br />calculations assuming approximately 75% of the vent area is net area unless the actual net <br />area is given from the manufacturer. <br />12. Specify make-up of one -hour fire resistive construction on the garage side for walls, <br />ceilings, posts and beams of garage adjacent to or supporting the dwelling/302.4. <br />13. Show on elevation view: chimney shall extend min. 2' (610mm) above any structure <br />within 10'-0" (3048mm). <br />14. Specify the following on plaits: <br />a. Grade and species of framing lumber <br />b. Treated foundation plats <br />c. Type and grade of plywood <br />d. Design strength of concrete <br />e. Design strength of glue laminated timber <br />f. Minimum reinforcing bar grade <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 259-8800 • Fax (206) 259-8856 �@ <br />