� GeoloEic lnvesliEafion nnd Geofech�nl !in¢ineerrn� Itennr! � 97-01-20 <br />r /229 hlndroiin Are. - Lo(1 <br />� (_l�cretf, IVnshingfon <br />Due to tlie moisture sensitivity of the site soil and to help maintain the long term stability of the adjacent <br />slopes, collected drainage and drain lines should not be discharged upon or over site slopes. Collected <br />water should be discharged at the base of the slope (aloirg the BNRR ditchline) or into an appropriate <br />storm water collector system through a tightlined Fipe. Tightline pipe should consist of non-jointed, <br />non-perforated pipe as specified in this section of the report. <br />Surface water run-off was noted during the siie investigation. We recommend utilizing shallow french <br />drains to collect surface water run-off along the eastern and northern sides of the proposed new home. <br />French drains should be a maximum four (d) feet deep, two (2) feet wide, and be backfilled with 5/8" <br />minus washed pea gravel wrapped inside of a:,trong, durable fil[er fabric. A minimum four (-!) inch <br />perforated PVC drainline should be placed at the base of the french drain laid on a minimum 1% grade <br />towards a point of discharge. Cleanouts should be placed at appropriate intervals to allow for adequate <br />maintenance of the system. <br />4.7 Earth Pressures Behind Wall <br />� All backfill placed behind walls or around the foundation should be placed as per the recommendations <br />given above or within this section of the report. The following recommended earth pressures are <br />Lpresented as equivalent fluid pressures and are based on the assumptions of a uniform, level, granular <br />backfill without buildup of hydrostatic pressures behind walls. To minimize earth pressures and prevent <br />�_ the buildup of hydrostatic pressures, wall backfill should consist only of free draining granular material <br />with draina�e provisions as described above. If the backfilled walls are structurally restrained from <br />�. lateral movement at the top, we recommend that the walis be designed for an equivalent weight of 50 <br />pounds per cubic foot (/�c� ro represent at rest pressures. lf the tops of the walls are free to move <br />laterally by an amount equal ro at least 0.1 percent of the wall height, they may be designed for active <br />conditions using an equivalent FluiJ pressure of 35 pcf. Surcharges due to sloping ground, adjacent <br />footings, vehicles, construction equipment, etc., must Ue added to these values. Only light hand-held <br />vibratory equipment should be used to compxct soil within 5 feet of all walls. <br />12 GES, Inc. <br />� <br />