Plan Check //40310 <br />July 7, 1993 <br />Page two of two <br />8. Provide smoke detectors in all sleeping rooms and in tiie corridor or area <br />giving access. <br />9. All below grade walls aze required to be insulated to minimum R-19 @ <br />the interior, or minimum R-10 rigid insulation at the interior. Show an <br />plans. <br />10. Provide detail/section of retaining wall at den/carport wa:ls with <br />unbalanced backfill exceeding 3'-6" and basement walls exceeding 8'-0" <br />shall be designed by a licensed Washington Siate Structural Engineer, or <br />walls with a surchazge. <br />11. Provide tempered glass at required hazardous loca6ons per 5406(d). <br />Show on plans. <br />In order for the processing of your application t�� continue, it will be necessary to <br />provide the Building Department with two complete new sets of drawings reflecting the <br />corrections requested. <br />Upon re-submittal of the drawings, your application will be given priority and plan <br />review recommence. <br />All requirEcl submittals shall be of sufficient detail and contain sufficient information to <br />ensure that the proposed suucture will be constructed in compliance with all adopted <br />codes. <br />Sincerely, <br />Jeff Heilman <br />Development Technician <br />.u�mPmen <br />