Laserfiche WebLink
'!!BL/C Iy0/�K5' <br />PCk48671 <br />July 12, 1995 <br />Page 3 <br />14. Specify the following on plans: <br />a. Grade and species of framing lumber <br />b. Treated foundation plates <br />c. Type and giade of plywood <br />d. Design strength of concrete <br />15. Provide assumed design loads on the drawings including b��t not limited to: <br />a. Seismic zone <br />b. Wind exposure and speed <br />c. Snow load <br />d. Floor live load <br />e. Deck live ]oad <br />f. Soil bearing pressure <br />g. Equivalent fluid pressure <br />16. Studs supporting two floors, a roof and ceiling cn.ust be 3x4 or 2 x 6 at lb" o.a. <br />17. Show all posts on plans including built-up 2 x's. <br />18. Specify the header size at openings over 4' wide in bearing walls, and where <br />point loads occur over windows and garage door. <br />19. Trace all loads all the way down to the foundaiion. <br />20. Show walls on roof Framing plans. Indicate bearing walls and point loads. <br />In order f'or the processing of your appliczdon to continue, it will be necessary to <br />provide the Building Division with two complete new sets of drawings reflecting the <br />corrections requested. <br />Upon resubmittal of the drawings, your applicadon will be given priority and plan <br />review will recommence. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 � <br />