Laserfiche WebLink
• ��i�S-o f� ' <br /> 11. Supports for solar modules are installed to spread[he dead�oad atross as many roof- <br /> freming memhers as needed to ensure that no point load exceeds fifty(50)pounds. ✓❑ ❑ <br /> (IRC M2302.2.1�5)� <br /> 12. The pliotovoltaic modules and supporting struc�ure shail 6e constructed of <br /> noncomhustible materials or fire-retardaot treated wood equivalent to that required for � O <br /> the roaf construction.(IRC M2302.2.1] <br /> 13. Roof and wall penetratfons shall be(lashed and sealed to prevenl entry of water, � � <br /> rodents,and Insects. �IRC M2302.2.2] <br /> 14. PV modules are listed and labeled with a tire classiFication in accordance with UL 1703. � � <br /> (IRC M2302.2.3] <br /> Commencs: <br /> L� If you answered yes to all of the above questions,the project qualifies for the over-the- <br /> counter permitting process. <br /> Q Submit this Checklist, Site Plan, and other required permit application forms to: <br /> (Insert contac[lnJo for jurisdiction having outhority] <br /> � As the property owner or authorized representative of the abo�e listed property,I attest that <br /> all infarmation in this checklist is accurete to the 6zst of my knowledge. <br /> Applicant Signature: �Y ` Date: 5I�ZI�5 <br /> Applicant Name iPlease Print): ,JeSS2 /�fld@fS011 <br /> --------TO BE COMPLETEU BY CITY STAFF------ <br /> QualificsforO7CBuildingPcrmlt7 ❑Yes ❑No PcrmltAppllcatlonp: <br /> Staff Initials Date: <br /> � <br />