My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1722 HOYT AVE 2016-01-01 MF Import
>
Address Records
>
HOYT AVE
>
1722
>
1722 HOYT AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2017 3:42:53 PM
Creation date
2/18/2017 3:42:36 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1722
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Apri1 22, 1974 <br /> QiT OP <br /> �) t everett <br /> 1�2 CLL {\asa�y C:TY NALL � 253�fil.�15 <br /> J�21 Sound Avenue cvoarr. w�swu:cro�� <br /> I:vcrett, Washington 98201 `°:°' <br /> 1l:SP[CTiO�� UEPAniNEtlT � <br /> Dcar Sir: <br /> An inspection c✓as made on thu duplex at 1722 Hoyl- ,lvenue April 15, 1974, <br /> on clie ground floor apartment and April 17, 1974 on thc �ccond iloor <br /> apartm::nt. <br /> ilic Pollowing corrections will be necessary: <br /> 7 . Hlectrical service equipment is inadequatc and o.�r iu�ed. ' <br /> 2. Stainaay light is wired with lamp cord and light fi::tur� is <br /> missing in Che Ueclroom in the daan stairs apartmeut'. <br /> 3. Insufficient outlets in some of the rooms. <br /> 4. Tuii in tl�e upper Uatl� room has a non code faucet, <br /> 5. Kit.;hen sink on the second floor is in violation ot Che <br /> plumi,ing code. <br /> In addition to thc aUove Ilousing Code Violations ��e �recor,t;�end tl�� <br /> tollowing PlumbinL and Clectrical Code violations be corrected; <br /> P1umUing Code - Lower Unit: <br /> 1. The kitchen sinlc is not venCed. (s trappod) <br /> 2. Thc caash basin in noC vented. (s trupped) <br /> . 'ilie baCh tuU is not vented. <br /> 4. The wastc line from tuU and wasli basin havc adverse �radc <br /> and arc improperly connected to the closet bend. <br /> 5, There are galvanized fittings in the waste lines. <br /> G. There are cast iron joinl's that are uoC poure�. <br /> P1umUin� Code - Upper Uni[: <br /> 1. T_ltere is a cross connection on Che bath tub. (P;.11 cpouC <br /> Uclow top of tuU) <br /> 2. The overtloca trim has Ueen removed from the tui�, <br /> 3. The wash basin taaste is reduced to 1" and puslied iilco :���i <br /> opening in the lcad waste ins'd�� the wall. The joi.nc is <br /> loosc and lcalcins. <br /> 4. 1'here are improper iittings and connecCi.on:; un dic 1-i[chen <br /> sinlc wasC�, <br />
The URL can be used to link to this page
Your browser does not support the video tag.