My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3312 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
3312
>
3312 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2022 2:16:07 PM
Creation date
2/18/2017 5:47:51 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3312
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 5, 2003 <br />pUBL/C K/O/uLs <br />;, <br />Mike Hanson <br />Great Dane Enterprises, LLC <br />15905 38`h Ave NW <br />Stanwood, WA 98292 <br />Subj: STOP WORK <br />Loc: 3"312 Hoyt Avenue <br />Dear Mr. Hanson: <br />On April 10, 2003 the basement of the specified property was inspected for construction without <br />permits. That inspection verified that the basement was being reconfigured into six sleeping rooms <br />(to include an exis[ing bath room) without building, plumbing or mechanical permits as required by <br />Section 103 of the 1997 Uniform Buitding Code (UBC) as adopted by the Ciry of Everett. <br />Therefore, this letter is to officially notify you to STOP WORK at the stated address pursuant to <br />UBC Section 104?.4. The following items delineate the necessary steps which must be followed in <br />order to avoid further action. <br />The house is no longer being used as a single family dwelling but a congregate residence. <br />As there are 10 or fewer persons, the occupancy classification remains R-3. If this is a <br />licensed care facility (licensed by either [he Washington Department of Health or the <br />Departcnent of Social and Health Services), then a copy of that documentation must be <br />submitted as separate codes apply per UBC Section 313.1. <br />2. The proposed sleeping rooms and existing bath-oom in the basement must be abated, and the <br />basement must be retumed to it's original condition, or an approved alternate. UBC Sec:ion <br />310.6.1 requires that a habitable space have a ceiling height of not less than 7 feet, 6 inches. <br />Kitchens, halls, bathrooms and toilet companments may have a ceiling height of not less <br />than 7 feet. Beams (spaced more than 4 feet on center) may have a height of 7 feet above <br />the floor. The height of the basement is approximately 6 feet (unfinished) and can not <br />compfy with this minimum requirement unless the house were either raised, and/or the t7oor <br />lowered. <br />3. Various beams and tloor joists within the basement supporting the first floor have been <br />modified to facilitate the basement conversion. Calculations and details must be submitted <br />for permit review to justify the new condition of the supporting structure andlor required <br />repairs. Per LBC Section 106.3.�, the calculations are required to be produced and stamped <br />(wet-sealed) by a desi�n professional (architect or eneineer) !icensed by the State of <br />Washineton. � <br />� <br />CITY C�= =VEFE i �•?200 Cadar Street • Everetl. 1NA 982Q1 •(4251 257-8800 • Fax (a25) 25 �-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.