My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3312 HOYT AVE 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
3312
>
3312 HOYT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2022 2:16:07 PM
Creation date
2/18/2017 5:47:51 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3312
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 21, <br />PUBL/C K/O?/i'S <br />ENG/NEER/NG / PUBLIC SERV/CES DEPARTMEAfT <br />AWR Construction Services <br />P.O. Box 2905 <br />Vit. Vemon, WA 98273 <br />Subject: Project: <br />Job Address: <br />Plan Check No: <br />Lear Mr. Rommel: <br />Hanson <br />3312 Hoyt Avenue <br />C0306-008 <br />Everett <br />� <br />tlll�l <br />2002 <br />In response to your application for a construction perrnit, your plans have been exrmined and you are advised <br />that the issuance of a permit is being withheld for the reasons listed below. These comments address building <br />issues only. Additional revisions or additions may be required by other departments (such as Utilities, Planning <br />or Fire). All references refer to the 1997 Uniform Building Code, as amended by the State of Washington <br />andlor Washington State Energy Code 2001 Edition, unless stated otherwise. <br />In erder for the processing of your application to continue, it will be necessary to provide the Building <br />Division with trvo complete new sels of d: awings retlecling the corrections requested. , <br />1. Revised plans do not show sufficient space for stairs to be constructed per the stair detail on Sheet B. <br />Revise plans to comply with requirements shown. <br />2. 2 x 8 floor joists nt 16" o.c. will not span 13'6". Provide ;ooting under all bearing walls, show on <br />foundation plan. <br />3. Minimum room dimensions are measured at the tloor (R-21 insulation requires minimum 5�/z" framing <br />caviry). Below grade walls are required ro be insula�ed. <br />4. Item #G from the pervious letter asks for a ist tloar framing plan (not lst floor plan). It is my <br />understanding that the ] st floor, floor joists have be�n modii!ed. Please darify if the 800r system has <br />been modified. <br />5. Provide dimensions on all new partitions. If laundry closet is framed such that hallway is less than 3'- <br />0" r_lear, framing would be required ro be changed. (Bedroom minimum dimension 7'-0" measured at <br />the tloor.) <br />Please prepare a response letter showing where each item in this correction letter is addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will recommence. <br />All required submittals shall be of su(ficient detail and contain sufficient information to ensure that the proposed <br />strucmre will be constructed in compliance with all adopted codes. <br />Sincerely, JE'/ <br />��� <br />Jeff Hcilman <br />Development Technician <br />CITY OF EVERETT • 3200 Cedar Street • Everett. <br />DFDVPLYCI:M57A/IIEILV AP'C0306009 i UI' II01"1' T\'eb I <br />WA 98201 •(425) 257-A200 e Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.