Laserfiche WebLink
- _ �.�. . <br /> �. <br /> .., � <br /> Plan Check No. 37190 <br /> Page Two of Two <br /> 9. Provide handrails and guardrails per Section 3306(j) and Section 1711 on each side of <br /> the front exterior porch stair. <br /> 10. Provide a smoke detector above the top landing of the main entry stair and in the <br /> basement per Section 1210(a)4. <br /> 11. Ensure storm windows are operable from the interior at sleeping room windows per <br /> Section 1204. <br /> 12. Provide a basement/foundation plan to indicate support for bearing walls above. <br /> 13. The 2x6 infill framing at the existing stair to second floor (removed) appears to be <br /> �msupported and the existing 2x10 floor framing at the removul beanng wall also <br /> appears to be unsupported.. Please clarify. <br /> 14. Submit evidence that existing roof structure is capable of supporting new overframed <br /> roof azeas. <br /> I5. Indicate exhaust fans, whole house fan for each unit and outdoor air inlets per <br /> V.I.A.Q. Code. Also r�ote that all fans and clothes dryers must vent to the exterior. <br /> 16. The energy calculation,e submitted do not comply. As this is an existing structure <br /> Section 101.3.2.4 woulo apply and it is the applicants opUon to meet the requirements <br /> listed below or to provide calculations that will comply with Chapter 5 of the <br /> W.S.E.C. <br /> Roof/ceil_ing - R30 minimum (R38 would be better) <br /> Exterior Walls - R13 minimum (R15 may be available for 3 1/2 inch thickness) <br /> New Glazing - U=0.65, 21`7o maximum area (23.67% shown) <br /> New doors - U=0.40 <br /> In order for the processing of your applicatiun to condnue, it will be necessary to provide the <br /> Building Departrrent with two complete ne•a• sets of drawings reflecting the correc�ions <br /> requested. <br /> Upon re-submittal of the drawings, your application will be given priority and plan review <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be conswcted in compliance with all adopted corles. <br /> Sinc /'� <br /> ����/r'�� �. ', <br /> e�S.�icFall <br /> soci t�Engineer/Building <br /> ry <br />