Laserfiche WebLink
• ANKROM MCISAN .4SSOCIATED ARCHITECTS EVERETTSENIORLIVINGGENTER <br /> ALS-Clare Bridge <br /> BUILDING CODE REVIEW 971076 <br /> 06/1 fil98 <br /> Applicable Code: 1994 UBC wifh 6/30/95 Washington State Bu;lding Code modi/ications. <br /> Occupancy Group: LC(sac.313J Licensed Care <br /> 313 Group LC Occupancies sh�ll include... use for the business of providing licensed care to clients ... <br /> regulated by eilher the Wash. Dept.of Health or the Dept.oi cocial and Health Services <br /> 7. Boarding Home w/Dementia Care <br /> 3132.1.1 Type of Construction. If over 16 clients or 3000sf above first story,shall not be Iess than 1 hr.fire resistive <br /> construction throughout. Limits per 504,505,506. <br /> 3t3.2.1.2 Araa and Height. LC occupancy shall not exceed,in area or height Table 5-B for R1 occupancies. <br /> Table 5-B ALLOWABLE AREA For R-1 (LC)Occupancy <br /> Sprinkle for Area: Type V-1 hr <br /> Table 58 Basic(1 fl.) 10500 <br /> 505.3 A�toSprinkler +300% <br /> 505.1.2 Sep.3 Sides + 100% <br /> Net Max/Fl. 63000 <br /> AC'fUAL PROPOSED AREA <br /> Allowable Area Comparison to Actual <br /> a) UnseFareted Single Bldg. LC=R1 <br /> Type V-1hr <br /> Build(ng Area 30750 OK <br /> � <br /> � <br /> NOTE: OK w/NO SEPARATIONS <br /> 313 Location on Property. ...compty with prov!sions fnr 3roup Rt. <br /> Table 5•A EXTERIOR WALL AND OPENING PROTECTION <br /> Occupancy Const.Type Bearing walls NonBearing Walls Openings <br /> R-1 V-1HR 1 hr. 1 hr None<�' <br /> 313.4.1 Evacuation Capability Classifcations of ability of clients to respond to emergency. <br /> Class I. Physically and mentally capable of walking or traversing normal path to safety...including stairs, <br /> and capable of self preservation,withoul physical assistance of anolher person. <br /> Class II. ..capable of traversing normal path...with use of mobility aids,but unable to ...stairs w/out assisfance. <br /> Class III. ... unable to walk or treverse a normal path without assistance. <br /> 313.4.2 Exit Facilities. LC occupant load facter of 1/300sf. Two Exits required for 10 or more occupants(client 8 staff). <br /> All other requirements of Chapter 10 per R1. <br /> 313.4.3 Accessibility. Comply with R1 Congregate Residences per Chapler 11. <br /> 313.4.4 Emergency Escape. All sleeping roems of class II or III clients shall be on a grade level floor which provides <br /> at least rivo means of egress which do not require clients to use stairs,elevator,or plaKorm lift to exit the facility. <br /> 313.4.4.2 Escape windows and doors. Every sleeping room below 4th story in�luding basements shall have at least one <br /> escape window or door opening into public street, all2y,yard or exil coun.5.7sf area,min.24"h, 20"w,44"sill. <br /> 313.5.5.3 Sanitation: 1 wc per 10 men, twc per 8 women, 11av per 12 men, 1 Iav per 12 women, <br /> plus when> 12 clients of either sex,add t lav per additional 20 men or15 women. (or fractional part thereotl. <br /> provide 1 tub or shower per 8.plus 1/30 additional women. where>150 clienls add 1 tub or shower/20>150. <br /> 313.6.2 Floor Area: At least one room minimum 120 sq.ft. Other habitaule rooms except kitchen, 70 sf. min. <br /> Other ha6itable rooms except kitchen 7 ft minimum in any dimension. <br /> 314 Exits shall Ge enclosed as specified in Chapter 10. <br /> I <br />