My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015 LAKE HEIGHTS DR 2018-01-01 MF Import
>
Address Records
>
LAKE HEIGHTS DR
>
2015
>
2015 LAKE HEIGHTS DR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2018 3:35:59 PM
Creation date
2/19/2017 12:19:08 PM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2015
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
: 314 Smoke detectors required zach sleeping room in licensed care facility <br /> Power source for smoke detectors from building wiring,and shall be equipped with battary backup. <br /> Smoke detedors lorated also at point centrally located in corridor giv�ng access to each separate sleeping area. <br /> Deteclors shall sound an ala�m audible in all sleeping areas of lhe iicensed care facility in which they are located. <br /> 313.82.1 Sprinkler uystems. Required with over 16 clients.Per UBC Standard 9-3<4stories. <br /> Residenti�l or quick response sprinkler heads are required. <br /> 314 Fire Alarm required with approved manual&automatic system.Local alarm behveen 15dba above ambient, <br /> 70 dba min., 110 dba max.,in every occupied space. <br /> 313 Special hazards. Slorege of Class I tlammable liquids must be behind 1hr fire door w/sign"FIRE DOOR-KEEP CLOSED" <br /> 310 REQUIR[41ENT5 FOR GROUP R OCCUPANCIES (RESIDENTIAL) <br /> 310.2.2 Walls�nd floors separatinS dwellirg units shal�be 1 hour. <br /> 310 See sec 503,and Ch.6 forfire resist.of exteriorwails and openings at property line. <br /> Table 6-A FIRE RESISTIS'E REQUIREMENTS Type V-1hr. <br /> Bearing Walls Exterior 1 hour Bearing Walls Interior 1 hour <br /> Non-Bearing Walls Interior 1 hour Siniclural Frame 1 hour <br /> PeAilions,permanenl 1 hour Shaft enclosures � hour <br /> Floors and Fioor Ceilings 1 hour Roofs and Roof Ceilings 1 hour <br /> Exierior doors,windows Sae 606.3 Stainvay Const. See 606.4 <br /> 311 Room Dimensions: Min.hl.ir�Ha6itable rooms 7-6, Kit.Hall,Bath,7-0. SeE exceptions. 7'min.horiz.dim. <br /> [ach Dwelling unit to have min.one ha6itable room of 120st,other habitable rooms,except kitchen,70sf min. <br /> 311 6cits shall be enclosed per ch.10. Enclose shafts,chules,openings per 711. <br /> 310.9.1 Smoke Detection...all dwelling units per manutacturers instructions. Hardwire+battery backup. <br /> Install detector...each sleeping room+centrally... in corridor or area giving acce�s to each sleeping room. <br /> 310.9.2 904.2.8 Sprinklers throughout required>3 stories,or 16 units. Residential or quick response standard heads. <br /> 904.3 Monitor valves and waler tlow switches when over 100 sorinkler heads. <br /> 310.10 An automatic and manual fue alarm system shall be provided>2 stories or 16 units. <br /> 708 �RAFT STOPS <br /> 708.3.1.1. Draft stop shali be installed in floor-ceiling assemblies of buildings other than dvrellings or hotel occupancie�so that <br /> area of concealed space does not exceed 9,000 sf and the horiz. dimension does not exceed 100' <br /> 1000 MEANS OF EGRESS <br /> 1002.1.1 Accessory use areas which ordinarily are used only by persons who occupy fhe main areas of an occupancy <br /> shall be provided wit exits as though they are completely occupied, but their occupant load need not be included <br /> in the total occupant load of lhe building. <br /> 1003 Every building or usable portion thero(shall have at leasl one exit, not less than 2 exils where required by table 10.A <br /> Table 70-A Minimum Egress Requirements <br /> Use: 2 exits> Occup. load factor <br /> Congregate Residence 10 300 <br /> 1003 Width. The total width of exits in inclies shall not ne less than occupant load x .3 for stairs,x.2 for other exits. <br /> 1004 Exils through adjoining rooms. Rooms may have o�e required exit throuc�h an adjoining room. <br /> Rooms wilhin dwelling uniis may exit through more than one intervaning room. <br /> Rooms wilh a cumulative�occupant lead of 10 or less may exit through more than one intervening�oom. <br /> 1004 Swing&opening force. Swing in"out"when serving hazardous occupancy or 50 or mora occupants. <br /> Exception: Doors within individual dwelling unit. <br /> t004 Type of Lock or Latch. Operable irom inside withoul use of key or special knowledge or eftort. <br /> 1005 Special egress-control devices. R1 congregate residences may be equipped with approved dsvices of time-delay type. <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.