Laserfiche WebLink
1005 Width 8 Height. Every required exit doorway shall pertnit installation of a 38"wide,6'-8"tali door, <br /> w/min 32"clear when open. In computing the exit width required by Sedion 1003.2,tha net dimension <br /> of the exitway shall be used. <br /> 1005 Floor levels at d�ors. Required accessible doors-1/2"max drop,non-required 1"max.drop. <br /> tU04 Landings at doors. <50 occupar.ts-Door fully open may reduce required landing dirn.by 7". <br /> 50 or>-Door in any position shall n�t reduc?landing dimension to less than one half its required width. <br /> Landing dim.in direction of iravel 44". <br /> 1U05 CORRIDORS <br /> 1005 Minimum width, if occupant load is 10 or more, is occupant load x G2"or 44"(36" if<50 occup), whichever is grester. <br /> 1103 ACCESSIBILITY <br /> 1103.1.8. Minimum number of accessible rooms in accordance with Table No, 11-C <br /> Table 11-C Number of Accessible Roams and Roll-In Showers <br /> Total Number o!Rooms Minirwm Acrzssible Unito Rooms w/Roll-In Showers <br /> 51-75 3 1 <br /> 1?03.1.9. Accessible units require accessible public and common use areas and facilities. <br /> 1103.2.3 At least 50%of all entrances or a number equal to tha number of exits in 9003.1 (excluding load/service <br /> entrances) to be accessible. <br /> 1104 EGRESS AND AREAS OF REFUGE <br /> 1104 Hccessible means of egress shall be provided in the same number as exils required by chapter 10. <br /> � <br />