My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2131 LAKE HEIGHTS DR 2016-01-01 MF Import
>
Address Records
>
LAKE HEIGHTS DR
>
2131
>
2131 LAKE HEIGHTS DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2017 12:47:52 PM
Creation date
2/19/2017 12:46:59 PM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2131
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
351
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� SECTION 8-20.3(14)D OF THE STANDARD SPEC[FIt�ATIONS IS SUPPLEMENTED BY THE <br /> FOLLOWING: <br /> I� &20.3(14)D Tesu for Induction Loops and Lcad-In Cablc <br /> I All tests shall be perfortned by the contracror in the presence of the engineer for each loop. The tess shall be <br /> performed at the amplifier location after complete installation of loop. All loops shall be tested for inductance, <br /> resistance, isola[ion,and induced voltage as defined below. <br /> Inductance - Loop inductance in micro Henry's shall be measured between the 2 lead in cable wires using an <br /> ( inductance meter. <br /> Resistance-The DC resistance behveen the 2 lead in cable wires shall be measured using a Volt Ohm Meter. The <br /> I resistance shali not exceed 15 Ohms per loup. � <br /> Isolation - A meg Ohm meter test at 500 volts DC shall be made between the lead in cable �hield and grounding, ! <br /> prior to connection to grounding. The resistance shall equal or exceed 50 megohms. � <br /> ( A megger test shall bc made behveen the loop circuit and grounding. The resistance shall equal or exceed 100 � <br /> megohms. <br /> IInduced Voltage - Induced voltage. between the 2 lead in cable wires shall be measured with a millivolt meter. � <br /> The induced voitage shall not exceed 1 volt at all locations. i <br /> � <br /> I If any of the installations fails to pass all tests, the loop installation, splice, or lead in cable shall be replaced ; <br /> entirely and the loop shall be retested until all tests have been passed. I <br /> All testing of loop detectors shall be incidental to the contract price for installing the loop detectors. <br /> i <br /> 8-20.3(14)F Loop Detector Lead-In Cablc{1 pair)(New Section) <br /> I Two conduc:or shielded #14 AWG lead-in cable conforming to IMSA Specification #50-2-1984 st.iall be installed <br /> where shown in the wiring schedule in the Plans. Where existing loop lead-in cable is present, the existing cable <br /> shall be pulled out and disposed of. The new lead-ia cable shall be spliced to the Ioop wires utilizint;a scotch cast <br /> I epoxy 82-81 splice kit or approved equal as detailed ir. Standard Plan ]-8a. Where the wiring scheduie in the <br /> plans calls for more than one loop detector to be spliced into a single lead-in cable, the loops shall be wired in <br /> series. The loop detector lead-in cable shall be pulled inro the controller cabinet and connected to the detector <br /> Ichanncl terminals as indicated in the loop detector schedule in the plans. <br /> 8-20.3(14)G Loop Detector Lead-In Cable(3 pair) (New Section) <br /> I Three pair loop detector lead-in cable shall be installed where shown in the wiring schedule in the plans. Belden <br /> 1037A is a preapproved source for this cable. Other cablec may be submitted for approval consistent with the <br /> following specifications: Three pair loop detector lead-in cable shall consist of three individually twiste� and <br /> I shieided pairs of It1G AWG stranded copper wire, surrounded by an euterjacket of polyvinyl chloride (PVC). <br /> Each pair shall also contain a stranded copper drain wire and shall be individunlly shielded with an aluminum <br /> polyester foil shield. <br /> I SECTION 8-20.4 OF THE STANDARD SPECIFICATIONS IS SUPPLEMIENTED BY THE <br /> FOLLOWING: <br /> ( 8-20.4 Measurement <br /> I "Telemetry Cable, Pair" shall bc RGA P-39 or P-38 as indicated on the plans and will be measured by the <br /> I linear foot for the acWal neat liae Iength in place. <br /> p:Wcwa00NN�WK�con�av.doc <br /> David fvans and 9'socioics,Ina SP-I1 7lh Ave.SP/IOOttwRt.Signal Modification <br /> lune1998 <br />
The URL can be used to link to this page
Your browser does not support the video tag.