Laserfiche WebLink
Final Monitoring REport Page 2 <br />00-2267-1 Hoban Residence Addition, Everett <br />February 23, 2002 <br />minute and the penetration aciiieved du� ing that period being recorded. Providing the <br />penetration was less than one inch the pile was considered acceptable. If the <br />penetration was greater than one inch, pile d�ving was continued until the refusal <br />criterion was met. <br />Based on the results of uur proof test monitorin� these pin-piles all achieved less than <br />one half inch of penetration. Thus, all of the installed pin-piles are considered to be <br />acceptable, and each is capable of developing in excess of four thousand (4,000) <br />pounds in allowable load bearing capacity. This meets, or exceeds, the original <br />project specifications. For informational purposes we have provided the results of the <br />pronf testing program in Table A, attached. Additionally, the identification numbers <br />and approximate pin-pile locations are shown on the attached Field Construction <br />Inspection Reports. <br />We appreciate the opportunity to have been of additional geotechnical assistance to <br />you on this project and trust that this information is sufficient to complete yc�ur project <br />records. Our work on this foundation construction phase of the project was <br />performed, and our opinions were d�rived, in a manner consistent with that level of <br />skill, care and competence ordinarily exercised by other members of the profession in <br />good standing currently practicing under similar conditions in this area only. No other <br />warranty, express or implied, is made. If you have any questions, or if we can be of <br />any further assistance, please call. <br />Very Truly yours, <br />CREATIVE ENGINEERING OPTIONS, INC. <br />Glen Mann, P.E. <br />President <br />Attachments: Field Construction Inspection Reports (2) <br />Table A; Pin-Pile Proof Test Data <br />grtVHoban Flnal Piling Monitoring RepoNebB4 <br />