Laserfiche WebLink
� c <br /> June 2,2010 <br /> Eileen Thornton I <br /> 8802 Shadow Wood Dr <br /> Everett WA 98208 <br /> Subject: Project: Thornton <br /> Job Address: 345 Heather Rd <br /> Plan Check No: C1005-010 <br /> Deaz Mrs.Thornton: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is bemg withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be required <br /> by other departments (such as Utilities, Planning or Fire). All references refer to the (2006 <br /> Intemational Building Code,) (2006 Intemational Residential Code,) as amended by the State of <br /> Washington and/or Washington State Energy Code 2006 Edition, and adopted by the City of <br /> Everett,urless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to provide <br /> the Building Division with two new complete sets of drawings reflecting the corrections <br /> requested. <br /> 1. The A35 framing an�le specified at the roof rafters is not intended for a"plate type" <br /> connection. Provide connector intended for a flat condition. <br /> 2. Specify hanger used at top and bottom of new 2x6 attached to existing 2x6 rafters. <br /> 3. Provide calculations for loading of new rafters and the attachment to existing rafters. <br /> 4. Plans call out an LSTA 24 at the south end of the new 5 1/8"x 18" GLB (the beam <br /> extends beyond the post supporting it). What is the strap tie transferring tension loads to, <br /> and in the location shown the LSTA would only be attached to the GLB. Please clarify. <br /> 5. �Provide strap tie(s) at discontinuous plate(s)in living room(where post supporting GLB <br /> interrupts double top plate); show on plans. <br /> 6. Provide egress window in new bedroom in the basement. Specify window size. <br /> 7. Provide GWB on walls and soflit of usable space under stairs per R311.2.2 IRC. <br /> 8. Fireblock alon�stringer at concealed spaces and at mid-run; show on plans. <br /> 9. All glazing located in hazardous locations as defined in Section R308 IRC shall be safety <br /> glass; show on plans. <br /> . kcollinMrtilmaNC1005�010(NSH�nhaAd) . � <br /> 3 <br />