Laserfiche WebLink
AMERICAN 110TEL ANP CIRCUS TAVIiRN <br /> January 17, 1972 <br /> 3) Service run has spliced conductors. <br /> 4) Fused and unfused conductors are run in the same raceway. <br /> 5) IInfused conductors are running more than 15 feet inside the building. <br /> ' 6) Panels are being used as a raceway. <br /> 7) Conductors are being used without proper fuse protection. <br /> 81 Knob and tuUe wiring is being used as conductors. <br /> 9) Metal raceways are required to,feed corridor light fixtures. <br /> 10) Exit liglits were nol illuminated, <br /> �Housing Znspection <br /> This stn�cture, which is being used as an apartment building with month to month <br /> tenants, cannot be classified as a hotel as the rooms are obviously not rented for <br /> sleeping purposes only. Zn this sense the swelling units of tlte hotel would be <br /> considered as suUstandard in tlie following way; <br /> 1) Violation oP ll13C Vol. III Sec. 11503(b) Superficial Floor Area. <br /> 2) Violation of U8C Vol. III Sec. H505(u) tiach unit shall be provided with <br /> a watcr clo.^,et, lavaCory and a UathtuU or shower. <br /> 3) Violation of UBC Vol. III Sec. 505(c) liacli dwelling unit shall be provided <br /> with a kitchen. Eac:l� Kitclien shall have a kitchen sinic. <br /> Fire Marshal's Inspection <br /> 1) East wall craciced. iQall Uulges. <br /> 2) SW Corner of Che Uuilding has a crack nnd also Uulges Chere. <br /> 3) Three property openi.ngs cacst .^,ide of the buildin�. <br /> 4) Exl'erior crack on crest w111. <br /> 5) Scrvice drop on roof is hrolcen loose and laying on the rooP. <br /> 6) Glass from tavern to exil' passageway from exiC doar to sidecvalk. <br /> 7) Glass at foot of stairs between sCairs and attic of tavern. <br /> 6) lxtension of fi.refrom the Ilewitt side L-o the apartment.s aUove possil,le hecause of <br /> unprotecLed �lass in tavern attic area. <br /> 9) Exit stairs have paper over plasl-cr. <br /> 10) Open stairs to all fl.00r.s; no floor separation. • <br /> TIIIRD I'IAOR: <br /> 1) Plastcr off around slryli�liC to thc Norlh and Lo the South. <br /> 2) Steam pipe breaches ccil.ing near apnrtment 1G. <br /> 3) Bsit signs ouL of service. Both north should Uc arrowed. ' <br /> 4) Glass window to verCical opening i.n men's balh. <br /> 5) No fire or draE� stops in cock lofc. Four PecC. <br /> SliCO�n FLOOR • <br /> 1) Clocic wire sCapled ta ccili.ng. <br /> 2) Dan�crous wiring in hal.l near alarm bclt. • <br /> 3) ApurCment 8 duor gaps 1t the l'op. <br /> 4) Stcam pipe Urcacl�es ceiling north of Aparlmenl' 5. <br /> 5) Aten's Ual-h Las plywood iaindow in[o vcrL•ical sLaft. ` <br /> 6) Aparqnent 9 h 10 doors gap aC Cop. <br />