My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2408 HIGHLAND AVE 2018-01-02 MF Import
>
Address Records
>
HIGHLAND AVE
>
2408
>
2408 HIGHLAND AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2022 2:48:04 PM
Creation date
2/20/2017 9:26:03 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND AVE
Street Number
2408
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 15, 1975 1� J <br />2408 Highland <br />The west exterior of the building shows peeling paint. Some deterioration <br />of wood members. The porch is in bad condition, should be repaired, steps <br />should be repaires. North side of the building appears to be in good <br />condition, this side of the building has some peeling paint, has a <br />hole in thd�llent pipe from the bathroom. Back stairs are in need of <br />repair.rafter flashing in need of repair. South side of <br />house appears to be in good condition, some peeling paint. General <br />appearance of exterior is fair. <br />East Bedroom: Improper overhead light connection, improper wiring of <br />light in closet. Living room all items appear to be satisfactory except <br />probably needs one more outlet,there are now three. <br />East bedroom: One outlet. Code requires four. Electrical outlet in <br />east bedroom is improperly fastened, it is loose. <br />Kitchen: Light fixture over sink improper, not switched, has pull chain <br />appears not to be grounded. Strainer to trap tail pipe connection leaks, <br />should be replaced. Just to south of door into kitchen on kitchen east wall <br />there is a low bare wiring. Wiring should be covered, should be one more <br />applia:.ce circuit at kitchen sink counter according to electrical code. <br />No outlet in dining nook. Laundry room 220 volt outlet loose, all wiring <br />exposed to the eutsi-det"-t — <br />leiling outlet in laundry room seems to be improperly installed, coulc be <br />a hazard. Baseboard heater in bathroom, appears to be scorching the <br />floor. Detected cross connection of water tank for toilet and ap"siphoned <br />ball cock to be installed in the toilet. <br />In rear bedroom there is a water heater hooked up in an alcove off of <br />the bedroom, appears to be elect ical. There is a set of stairways leading <br />to the attic area constructed a to compliance to the Building Code. <br />There is one outlet in the bedroom, there is a switch on the east <br />wall of the bedroom. Again appears the bedroom may be under <br />ventilated, and improper exiting to the outside. <br />Upstairs attic area appeared to be lived in, wiring had been installed, <br />Checked records in office and no permits have been issued for electrical <br />since 1970.'? - T <br />