My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2810 HIGHLAND AVE 2018-01-02 MF Import
>
Address Records
>
HIGHLAND AVE
>
2810
>
2810 HIGHLAND AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2022 2:56:54 PM
Creation date
2/20/2017 9:28:30 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND AVE
Street Number
2810
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
April 4, 2000 <br />Gary Parkinson <br />2812 Colby <br />Everett WA 98201 <br />Subject Owner: Prime Equipment <br />Job Address: 2810 Highland <br />Plan Check No.: B0003-035 <br />Dear Mr. Parkinson: <br />in response to your application for a construction permit, your plans have been examined and you are <br />advised that the issuance of a permit is being withheld for the reasons listed below. These comments <br />address building issues only. Additional revisions or additions may be regtired by other departments <br />(such as Utilities, Planning or Fire). All references refer to the 1997 Uniform Building Code, as <br />amended by the State of Washington and/or Washington State Energy Code 1997 Edition, unless stated <br />otherwise. <br />In order for the processing of your application to continue, it will be neceseary to provide the <br />Building Division with two complete sets of drawings reflecting the corrections requested. <br />The submittal indicated the 6,120 sq. ft existing building to be non-sprinklered. City Ordinance <br />No. 1902-92 prohibits increasing its area without sprinklering it as well as the new addition <br />(canopy excluded). <br />2. The shear walls appear insufficiently designed and detailed. Calculations indicate 14 ft. of length <br />at the lower level front where the drawings indicate 9-1h ft. The floor plans indicate six different <br />types of shearing walls where the shearwall schedule indicates two. The holdown schedule is <br />incomplete. Holdowns of the upper level, front left shear walls have nothing below to attach to. <br />Construction documents for the canopy must be submitted prior to issuance of a building permit. <br />Please prepare a response letter showing where each item in this correction letter is addressed on the <br />plan set. <br />Upon resubmital of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, I <br />Steve Miller <br />Associate Engineer, P.E. <br />SM.jMW3-035 <br />CITY OF EVERETT• 3200 Cedar Street 9 Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.