My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1809 HOLBROOK AVE 2018-01-02 MF Import
>
Address Records
>
HOLBROOK AVE
>
1809
>
1809 HOLBROOK AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2022 12:44:18 PM
Creation date
2/20/2017 9:51:02 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLBROOK AVE
Street Number
1809
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Terhune Homes, Inc. JN 99028 <br />February 25, 1999 Page 3 <br />review would be additional work beyond the current scope of work for this study, and it may include <br />revisions to our recommendations to accommodate site, development, and geotechnical <br />constraints that become more evident during the review process. <br />Conventional Foundations <br />The proposed structure can be supported on conventional continuous and spread footings bearing <br />on undisturbed, competent, native, silty sand, or on structural fill placed above this competent, <br />native soil. See the later sub -section entitled General Earthwork and Structural Fill for <br />recommendations regarding the placement and compaction of structural fill beneath structures. <br />Adequate compaction of structural fill should be verified with frequent density testing during fill <br />placement. We recommend that continuous and individual spread footings have minimum widths <br />of 12 and 16 inches, respectively. They should be bottomed at least 18 inches below the lowest <br />adjacent finish ground surface. The downslope perimeter and deck footings should be placed at <br />least 5 feet below the existing grade. The local building codes should be reviewed to determine if <br />different footing widths or embedment depths are required. Footing subgrades must be cleaned of <br />loose or disturbed soil prior to pouring concrete. Depending upon site and equipment constraints, <br />this may require removing the disturbed soil by hand. <br />Depending on the final site grades, some overexcavation may be required below the footings to <br />expose rompetert, native soil. Unless lean concrete is used to fill an overexcavated hole, the <br />overexcavation must be at least as wide at the bottom as the sum of the depth of the <br />overexcavation dnd the footing width. For example, an overexcavation extending 2 feet below the <br />bottom of a 2-foot-wide footing must be at least 4 feet wide at the base of the excavation. If lean <br />concrete is used, the overexcavation need only extend 6 inches beyond the edges of the footing. <br />An allowable bearing pressure of 2,000 pounds per square foot (psf) is appropriate for footings <br />supported on competent, native soil. A one-third increase in this design bearing pressure may be <br />used when considering short-term wind or seismic loads. For the above design criteria, it is <br />anticipated that the total post -construction settlement of footings founded on competent, native soil, <br />or on structural fill up to 5 feet in thickness, will be about one-half inch. <br />Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and <br />the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the <br />foundation. For the latter condition, the foundation must be either poured directly against relatively <br />level, undisturbed soil or be surrounded by level structural fill. We recommend using the following <br />design values for the foundation's resistance to lateral loading: <br />Parameter <br />Design Value <br />Coefficient of Friction <br />0.40 <br />Passive Earth Pressure <br />300 pcf <br />Where: (i) pcf is pounds per cubic fool, and (it) passive earth <br />pressure is computed using the equivalent fluid density. <br />GEOTECH CONSULTANTS, INC. fG <br />
The URL can be used to link to this page
Your browser does not support the video tag.