Seismlc Conalderallons <br /> Construction should be in accordance with current Unifocm Building Code <br /> (UBC)related to potential seismic loading for the region. 'Ilie propecty is <br /> located within the Puget Sound region which has been clazsified u a Zone 3 <br /> seismic area. According to Table 16-J of the 1997 UBC(Apptndir),the soils <br /> should be clazsified as Sc. <br /> Potentlal Settlement <br /> If the foundations are placed upon the dense native soils pad as recommended, <br /> the settlement that can be expected is in the range of one-half to one inch. Any <br /> settlement which occurs will most likely take place during conswction. <br /> Overall,differentiai setdements that can be anticipated are about one-half inch. <br /> Slab-on-Grade <br /> The interior slab-on-gwde should be placed upon a capillary break which may <br /> consist of a compacted swctural fill. This will serve as both a compacted mat <br /> for floor support and a capillary break as long as the fill is ftee dtaining. We <br /> further recommend that an impervious moisture bamer be placed beneath the <br /> slab. If the slab is placed upon a properly compacted base,a modulus of <br /> subgrade reaction of 200 pci may be utilized. <br /> Retalning Structures <br /> For the design of basement ataining walls, a tluid equivalent pressure of 40 <br /> pcf may be assumed if the wall is allowed to yield an amount equal to 0.001 <br /> times its height. Walls that are not allowed to yield should be designed to <br /> withstand fluid equivalent pressures of 55 pcf. Walls backfilled at the base i <br /> with native soils may resist 250 pcf for an equivalent passive resistance and a <br /> 035 ccefficient of friction used for sliding. The pressures given allow for <br /> shorc-tecm loading during a one in 100•year seismic event and assume a I <br /> drained condition with no static water build-up and level backfill. In the event <br /> of sloping backfill,an additional one pcf should be added for each degree of I <br /> slope inclination behind the wall to a maximum of 33 degrees. Slopes behind � <br /> the retaining walls should not exceed 33 degrees or 1.SH:1 V. <br /> � <br /> Backfil! adjacent to the retaining walls should consist of a suitable free- ; <br /> draining granular fill. Granular soil fill should be a moderately to poorly- <br /> graded sandy gravel with less than five percent fines capable of passing a I <br /> standard U.S. No. 200 sieve. Granular fill should be placed next to the <br /> foundaiion wall, fortning a 12-inch vertical layer that will provide drainaFe. <br /> Fill matenal placed outside of the 12-inch drainage layer should be compacted <br /> in horizontal layers to a non-yielding condition. Fill material should be keyed <br /> into the native soils adjacent to the excavared foundation. Gravel drain rock <br /> should be placed at the base of the drain and should be protected from the <br /> Port Gartlner Condominiums•GeotecDnical Report �9e 7 <br />