My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1920 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
1920
>
1920 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 5:22:20 PM
Creation date
2/20/2017 5:21:48 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
1920
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
195
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� . � <br /> ' , . <br /> Plans for any such system shall be submitted to the Building Department and the Ever�;tt Fire <br /> Depart�nent for examination and approval. Such plans shall include plans for the underground mains <br /> that will supply the sprinkler system. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br /> for private f re mains. All such tests shall be witnessed by a Fire Depa�:ment inspector. Call (425) <br /> 257-8123 to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Evecett I�ire IIepartment prior to <br /> issuance of any Certificates of Occupancy. <br /> Call(425) 257-5123 for more information. <br /> 22. Fire Safetv-Fire safety practices during construction shall be in compliance with Article 87 of the <br /> Unifortn Fire Code. <br /> 23. Demolition of buildings shall be in compliance with the provisions of Uniform Fire Code, Section <br /> 8?06"Firesafety during Demolition"(copy attached). <br /> 24. The City of Everett prohibits outdoor buming. Therefore,outdoor buming for the purpose of <br /> disposing of construction debris or rubbish will not be permitted. r <br /> 25. Trash Collection-Dumpsters over 1.5 cubic yazds capacity shall be located a minimum of 5 feet from , <br /> the building(UFC 1103.2.2, 1994 Edition]. <br /> 26. Placement and screening of refuse disposal areas must be provided per Section 39.080 of the 7_oning <br /> Code. Gazbage receptacles, dumpsters, aud recycle bins shall be provided in all multiple family, <br /> commercial, industrial aud institutional developments and shall not be located in a required front yard <br /> setback arca, or s.reet side setback area for corner lots. Where an alley abuts a lot, the garbage <br /> receptacles, dumpster, or recycle bin shall be located adjacent to the alley. ! <br /> i <br /> All garbage dumpsters and recycle bins must be screened from view from the street and from adjacent <br /> properties. This screening may be done using dense vegetation or by placing the dumpster or recycle � <br /> bin in a struchiral enclosure. � <br /> 27. Parking must be per City Zoning Code and City Design and Construction Standards and <br /> Specifications. 1.5 parking stalls must be provided for dwellings with 2 or more bedrooms per <br /> Historic Zoning Overlay Standazds. A minimum of 2 accessible spaces must be provided. <br /> 28. Any rockeries or retaining walls proposed in required se,.back areas must be in conformance with <br /> Section 3�.150 of the Zoning Code, unless a modification is approved. <br /> 29. Rooftop mechanical �quipment, induding vents, must be screened per Section 39.040 of the Zoning <br /> Code. <br /> / <br />
The URL can be used to link to this page
Your browser does not support the video tag.