' <br /> GEOTECHINCAI HJGINEERING STUDY E-12863 <br /> � Narch 17,2007 <br /> ' Horizontal loads can be resisted by friction between the base of tlie foundation and the <br /> supporting soil and by passive soil pressure acting on the face of the buried portion of the <br /> foundation. For frictional capacity, a coefficient of 0.35 should be used. Resistance due to <br /> � passive earth pressure may be computed using an equivalent fluid pressure of 300 pounds <br /> per cubic foot (pc� for footings backfilled with structural fill. These values are allowable <br /> values; a factor-of-safety of 1.5 has been included. As movement of the foundation elert�ent <br /> 1 is required to mobilize full passive resistance, the passive resistance should be neglected if <br /> � such movement is not acceptable. Unless covered by pavements or slabs, the passive <br /> resistance in the upper 1 foot of soil should be neglected. <br /> � ECI should be retained to observe the foundation subgrade prior to placement of structural <br /> fill, forms, or rebar. <br /> � Slab-on-Grade Floors <br /> I Slab-on-grade floors may be supported on competent native soil or structural fill. Loose or <br /> disturbed subgrade soil must either be compacted to the requirements of structural fill or <br /> replaced with structural fili. <br /> � Slabs should be provided with a capillary break comprised of a minimum of 4 inches of free- <br /> draining sand or gravel. In areas �+vhere slab moisture is undesirable, a vapor barrier, such as <br /> , a 6-mil plastic membrane, should be placed beneath the slab. <br /> � Retaining Walls <br /> Retaining walls should be desiyned to resist the lateral loads imposed by the retained soils <br /> � and applicable surcharge loads. <br /> � Walls that are designed to yieid can be designed to resist the lateral earth pressures imposed <br /> i by an equivalent fluid with a unit weight of 35 pcf. If walls are to be restrained at the top from <br /> � free movement, the equivalent iluid weight should be increased to 50 pcf. These values are <br /> based on horizontal backfill conditions. Surcharges due to backfill slopes, hydrostatic <br /> I pressures, traffic, structural loads, or other surcharge loads are assumed to not act on the <br /> wall. If such surcharges are to apply, they should be added to the above design lateral <br /> pressure. <br /> � For seismic design, a rectangular distribution equal to 7H psf, where H is the height of the <br /> wali, should be added to the earth pressure for yielding walls. The passive pressure, <br /> , allowable bearing capacity, and friction coefficient previously provided in the "Foundations" <br /> section are applicable to the retaining wali design. <br /> To reduce the potential for hydrostatic pressures to build up behind the walls, retaining walls <br /> � shouid be backfilled with a free-draining material extending at least 18 inches behind the <br /> wall. The free-draining backfill should consist of either pea gravel or washed rock. A rigid, 4- <br /> � inch-diameEer, schedule 4�, perforated PVC drain pipe shoufd be placed at the base of the <br /> i wall and should be surrounded by a minimum of 1 cubic foot per lineal foot with pea gravei or <br /> washed rock. The pipe should be placed with the perforations down. The remainder of the <br /> i backfill should consist of structural fill. <br /> � EARTH CONSUITNG INCORPORATED P;re; <br />