My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2620 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
2620
>
2620 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2017 4:43:28 PM
Creation date
2/20/2017 7:44:29 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2620
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fr <br />(� <br />✓9. The construction at the interior stairs on all units should be shown in seclion, and <br />include a cross section indicating a wall or guard on the main plan for all units. IBC <br />section 1013 and R312.1 <br />vio. Guard details and dimensions should be shown on the drawings where the elevation <br />di(ference exceeds 30" at the main level porch for Units C and D. IBC section 1013 <br />� i I. Please remove the plumbing fixture table R307 diagram from the drawings, since it has <br />not been adopted by the State of Washington. The following information should be <br />shown on the drawings for fixture ciearances. UPC 402.5. <br />c. 15 clear from fixtures to wall or to an obstruction. <br />b. The finished height of the nonabsorbent wall surfaces to 70 inches above the <br />drain inlet in the shower should be shown on the drawings. IBC 1210.2.4 <br />c. Waterproof joints between the shower assembl�� and the wall should be shown <br />on Units C and D. IBC 1210.2.4 <br />d. The dnwing of the shower does nof appear to have adequate dearance between <br />the toilet and the door-field verify. <br />✓iz. Please remove the garage dwelling separation R30Z.6 table from the drawings, since it <br />is not applicable to a pubiic garaae. A one hour fire resistance rated separation behveen <br />the garage and the msidences above should be shown and defailed on the drawings, to <br />reference a one hour tested assembly with IIC 50. IE3C 406.4, IBC 508.1, Table 508.4, <br />IBC 1207.3 <br />a. Clear height in the garage shouid be shown in section as 7 feet. IBC 406.4.1 <br />b. Floor surfaces should be sloped towards a drain or the vehicle access doorway. <br />IBC 906.4.5 <br />13. Please cross-referencc the sections of wails separating uni[s on lhe plans. <br />�19. Please remove reference to area separation walls on sheeC 7 <br />d. Roof lrusses should be shown offsel af bearing wall bclwecn units, �ypical. <br />c Thc rated wall separatin9 unils C and D is required to have 50 STC sound, noC <br />shown on lhc drawings. Plcase submil a revised detaiL IBC 1207.2 <br />f. Plcasc mmove raled ass�mblics lhat are not refcrenced on this projcct: GA File <br />number 3360, 3870. <br />g. A tv��o hour fire separ�tion wall is referenced on Units C and D in the garage. <br />Pleasc verify. <br />h. Rating should be shown in a delail conlinuously [o thc undersidc of lhe roof <br />sheathing, maintaining the rating through and abovc the roof frusses. R307_. <br />1(�C 70f3.4 <br />� 15. 6uilding cnvelope requiremenls for compliance with lhe energy code should be shown <br />on lhe drawings. WSf_C Table R402. t.l. <br />