My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2620 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
2620
>
2620 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2017 4:43:28 PM
Creation date
2/20/2017 7:44:29 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2620
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,^ ( �P`��`"� ( y� oP <<,N Z,�R <br />a. Exterior walls: f�l; Exterior Wind�iws: U=.�� Floors: R- �,; ��'lings: K�. <br />/ . 28 '�tb <br />✓b. Please indicate the water heater and mquired insulation on the drawings. If it is <br />gas powered, the combustion air ope� ����gs should be shown on the drawings. <br />3a <br />c. R-�34 insulation required under stairs. Specify stringer size and quantity. Show <br />stringer attachment to main floor joists. <br />d. Please locate the vapor barrier on the wall, roof, and floor insulalion details. <br />e. Please indude a venting and insulation detail for Units C and D that includes a <br />rated eaae The dimensions of the projecting eave should be shown all urits. <br />✓��,��� <br />�6. The method of compliance with the whole house ventilation system, including vented <br />windows or through the wall ports, should be shown and defailed on lhe drawings. <br />a The whole house ventilation table on the drawings is not correct, and should be <br />replaced with current code mquirements. Tables M1507.3.3 (i and 2) 1MC <br />Tables 403.8.4.2 and 403.8.5.1 <br />b. Intermittenl or continuous operation of the whole house fan should be identified, <br />and the fan sizing should be shown on the drawings to meet minimum <br />requirements. The maximum sone rating is 1, not 1.5 as shown. Please update. <br />� 17. Tempered glazing should be shown at all locations required. R308.4 ar�d 1F3C 2906.4 <br />/' �u{ia�--J� iFc <br />� 18. Emergency escape egress window maximum height and minimum�pening area should <br />be shown on the drawings for all sleeping rooms, measured to th opening not thc <br />finished sill. R3]0.1 and IBC 1029 <br />c% 19. Fxlerior stairway illumination should be provided lo ihe garage. R303.7 <br />Applicable codes indude the 2012 Infernational Building Code (I[3C), the 7_017_ Inlernational <br />Residential Code (IRC), the 7_012 lnlernafional Fire Code (IPC), the 20.L2 Internafional <br />Mechanical Code (IMC), the 2012 Washington State Energy Code (WSEC), and the 2012 <br />Uniform Plumbing Code (UPC) as amended by the by the State of Washington and adopted by <br />the Cily of [verefC All required submiftal, shall be of sufficienl detail and contain sufficient <br />in(ormation to ensure lhat lhe proposed structure will be conslrucfed in compliancc with all <br />adopfed codes. <br />Plan f�eview A'chited <br />�7_5-7__7-II81� Email: mhaley_��everettwa.�ov <br />
The URL can be used to link to this page
Your browser does not support the video tag.