Laserfiche WebLink
March 30, 1972 <br />Coast Mortgage Company <br />P.O. Box 1051 <br />Everett, Washington 98206 <br />Gentlemen: <br />TF.is is to certify that an inspection of the dwelling located at <br />2628 Grand was made by the Housing Inspection Division r.ad the <br />structure meets the minimum requirements of the Uniform Building <br />Code, Volume III except as noted below. <br />Plumbing: <br />1. Water heater deem not have temperature and pressure <br />relief valve with proper discharge. <br />2. Basement toilet is not vented, nor is there a stop <br />on the warp: supply. <br />Electrical: <br />1. Service does not comply with code. <br />2. Kitchen does not have two utility circuits. <br />3. Clothes washer does not have separate circuit. <br />4. Wiring in basement does not comply with code. <br />5. Wiring to light on back steps, does not meet code. <br />6. All wiring should comply with N.E.C. 410-95. <br />Miscellaneous: <br />1. There is no handrail on basement stairway. <br />2. Basement toilet room does not comply with code. <br />Yours truly <br />Hobert K. Royce, Supervisor <br />Housing Inspection Division <br />By: Bruce Buck <br />Housing Inspector <br />RKR:bb.eb <br />aa; John Farrens <br />