My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3022 GRAND AVE 2018-01-02 MF Import
>
Address Records
>
GRAND AVE
>
3022
>
3022 GRAND AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2022 12:56:06 PM
Creation date
2/20/2017 8:30:41 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
3022
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�j� .� v .,,v_•�._r. _v- — - .... .�..,r,PyR .,.y, " �{a,"r.""'"_ t...,P:.-y-r-�+— .�:. ,:� <br />the _ _ n <br />May 26, 1971 CITY Of <br />everett <br />CITY HALL . 259.5695 <br />EVERETT. WASHINGTON <br />9u0I <br />INSPECTION DEPARTMENT <br />Tyee Mortgage Co. <br />2612 Wetmore <br />Everett, Washington 98201 <br />Re: 3022 Grand, Everett, Washington <br />Dear Sir: <br />An Electrical Inspection was made as requested on the property at <br />3022 Grand for F.H.A. requirements of minimum standards. The <br />following are items that must be corrected: There has been consider- <br />able wiring illegally added in the basement, that is not properly <br />spliced and does not terminate properly in boxes. Florescent fixtures <br />cannot be directly mounted on combustionable material whet, improper <br />temperature rated wire is used and no inline fuses in the ballasts. <br />New wiring does not properly terminate in the service panel. All <br />circuits are overfused. Grounding type receptacles have been installed <br />in the kitchen, bedrooms and living room, but are not grounded. <br />Receptacles in the kitchen are not on appliance circuits as required <br />by code. The lights in the kitchen cabinets, bedroom closets, and the <br />bathroom storage area are in code violation by virtue of location and <br />wiring methods. <br />Additional outlets are needed in the front room on the East wall. If <br />in properly circuiting the house in making these corrections and the <br />panel cannot accomodate the extra branch circuits, then a new panel <br />must be installed in place of the existing panel used. <br />Yours truly <br />L.J. DOUGHERTY <br />ELECTRICAL INSPECTOR <br />LJD:eb <br />
The URL can be used to link to this page
Your browser does not support the video tag.