Engineors/Consultants <br />Job#4057 <br />180ct09 <br />To: Chris & Todd Chase / Everett, WA <br />From: Frank Pita, PE / Geotecimical & Civil Engineer <br />RE: Engineering Comments / Concerns After Reviewing the Four Sheet Retaining <br />Wall Design by CG Engineering (dated 24Sep09 / Job#09117.10) for the Anderson's <br />at 4704 Harbor Lane, Everett, WA / Everett Plan Check No. 80910-019 <br />I will comment on each sheet in order and summarize at the end. <br />Sheet SO.1 <br />• In the Scope of Work section; the designer states that his work will '...stabilize <br />the existing slope.' 1 disagree with this statement. This soldier pile wall will <br />ONLY prevent the top few feet of the hillside from eroding or failing but in will <br />NOT make the hillside stable. Much more work is needed to do that. I <br />recommend that the scope of work should be re -written to be more specific to <br />what they are actually doing. <br />• On the Site Plan there are several un-answered issues: <br />o The surveyed pile of yard waste; is it to remain? Is it being placed there <br />illegally in that it is dumping of material that is on the side slope of creek <br />and could easily create a landslide onto adjacent property? <br />o The north end of the wall is NOT detailed from an earthwork aspect. The <br />contours do not show how the backfill is tied into the existing ground and <br />the property to the north. The concern is will this work cause erosion or a <br />landslide on the property to the north. <br />o No elevations are given for the property on the southeast side of the house. <br />Sheet SLI (the text portion) <br />First column; <br />• Code: designer refers to 113C, but does not the City of Everett, like most <br />Washington Cities, use WSDOT specs as there standard design code? <br />• Design Loads.... 3"t paragraph: indicates that '...lessor of 2 pile diameters...' <br />the question is did the design use the steel width or the diameter of the hole? <br />• Allowable grout to soil adhesion.... Where did value come from? There is no <br />reference. <br />Second column; <br />• Erosion...: this designer refers to the geotech report for specifications but the <br />geotech report is NOT complete and refers to the 'wetland' firm, which is not <br />complete either. Therefore, the conclusion has to be that Erosion and <br />Sedimentation is NOT being control properly. The recommendation to carry the <br />water to the bottom of the ravine still requires an agreement with the adjacent <br />property owner which is not discussed. <br />1109 1" Avenue, Suite 501, Seattle, Washington 98101 Phone: (206)5884200 Fax: (206)588-8201 <br />Page I <br />i371y <br />