My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4801 HARBOR LN 2018-01-02 MF Import
>
Address Records
>
HARBOR LN
>
4801
>
4801 HARBOR LN 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 3:15:43 PM
Creation date
2/20/2017 10:29:08 PM
Metadata
Fields
Template:
Address Document
Street Name
HARBOR LN
Street Number
4801
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering f .ort ( J-1280 <br />Johnson F esidence Addition 27 February 2002 <br />Everett, Washington Page 7 <br />experienced geotechnical professional prior to pouring foundation concrete or prior to mud slab <br />placement. <br />Lateral Resistance <br />An allowable coefficient of base friction equal to 0.4 may be utilized when evaluating <br />lateral resistance. A maximum allowable passive resistance of 100 pcf may be applied to <br />foundations with at least 18 inches of embedment into the recommended bearing stratum, <br />neglecting the upper 12 inches. The recommended maximum allowable passive resistance <br />includes a factor of safety of at least 2, and includes a reduction considering potential removal of <br />soils from the downhill side of the foundation in the event of a landslide. <br />Foundation Drainaize <br />We recommend equipping the residential addition with an interior perimeter footing <br />drain. The drain should consist of a minimum 4-inch diameter rigid perforated pipe embedded in <br />at least a 6-inch thick envelope of clean, free -draining granular material, such as WSDOT Gravel <br />Backjill for Drains (Publication M41-10, 2000). Footing drains should be directed toward <br />appropriate storm water drainage facilities at the toe of the slope that extends below the dwelling <br />toward Belvedere Lane. Drains should not terminate on or above the steep slope. Roof drains <br />should not be connected to the footing drains in such a fashion that water from the roof drains <br />could enter the foundation drain. <br />Backfilled Walls <br />The foundation wall should be considered a retaining wall in the event that backfrll is <br />placed against it. All backfrll placed behind the dwelling addition foundation walls and around <br />foundation elements should be compacted to at least 90 percent of the modified Proctor <br />maximum dry density (ASTM: D-1557). The following recommended earth pressures, <br />presented as equivalent fluid weights, are based on the assumption of a uniform level granular <br />backfrll with no buildup of hydrostatic pressure behind the wall. To minimize lateral earth <br />pressures and prevent the buildup of hydrostatic pressures, the wall backfrll should consist of a <br />free -draining granular material coupled with a perforated pipe drain placed at the base of the wall <br />as described above. All backfrll within 24 inches of the wall should contain less than 5 percent <br />fines, based on the portion passing the U.S. No 4 sieve, and have at least 30 percent retained on <br />the U.S. No. 4 sieve. <br />If the backfilled walls are structurally restrained from lateral movement at the top, we <br />recommend that they be designed for an "at -rest" equivalent fluid weight of 50 pounds per cubic <br />foot (pcf). If the tops of the walls are free to move laterally in an amount equal to at least 0.1 <br />percent of the wall height during placement of backfrll soils, they may be designed for an <br />"active" equivalent fluid weight of 35 pcf. Seismically induced dynamic lateral load increases <br />on the foundation wall may be modeled as a rectangular pressure distribution additive to the <br />values described above. The ultimate lateral earth pressure increase due to seismic loading is <br />Zipper Zeman Associates, Inc. <br />I18905 334 Avenue Wat, Suite 117 Lynnwood, Wuhinaton 98036 (425) 771 •3304 <br />r <br />
The URL can be used to link to this page
Your browser does not support the video tag.