Laserfiche WebLink
� <br />� <br />Subjecl: Proposed EI Sabor de Chihuahua, 7405 Hardeson Road #B, Everett <br />February 18, 2014 <br />Page 2 <br />partition of at least 1%. inch in thickness (similar to the partitions in restroom stalls) from the floor to <br />at least 16 inches above the sink basin �f a material that is waterproof. <br />9. When splashguards (partitions and/or walls) are provided on both sides of a handwash sink the <br />distance between the splashguards must be at least 18 inches apart (shoulder width) to atlow <br />proper access to the handwash sink. <br />10. Water heaters must be of sufficient size to provide hot water to dishwasher and/or sculiery sinks <br />and at the same time provide hot water to all handwash sinks. <br />11. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br />must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperationai <br />inspection. This is required so that proper testing of the 15-second time requirement for hot water <br />availability can be completed. <br />12. All food service equipment; both new and used, must be listed by the National Sanitation <br />Foundatron (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of <br />holding focd at temperature of 41 °F or below. <br />13. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br />food service establishment. Used equipment rnust be clean, in proper operating condition, and in <br />good repair. Used refrigeration must be capable of holding at a temperature of 41 °F or below. <br />14. Extra wall proteclion is required an walls behind all sinks, including restroom handwash sinks, and <br />food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br />reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall <br />behind counter top eqwpment taller than 16 inches. Wall protection behind mop sinks must cover <br />the entire splash zone. Plastic coated hardboard is not acceptable. <br />15. All floors in the kilchen, food preparation, food service, food storage, and disFwashing areas must <br />be surfaced with a durable, nonabsorb?nt, easily cleanable material. Fxpansion joints, seams, saw <br />cuts and the like in concrete tloors in all areas, inciuding customer seating areas, must be filled and <br />sealed so as to p!ovide a smooth and cleanable suriace. <br />16. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br />easily cleanable. <br />17. Cabinet sheiving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br />surfaces are not acceptabie) <br />18. All light fixtures in food preparation and storage areas must be provided with covers and <br />shatterproof bulbs. <br />19. Plumbing must i��eet state and local codes. <br />20. It cannot be determined from the floor plan or in`ormation submitted whether or not a chemical <br />dispensing system will be installed at the mop sink. Please note that the use of screw-on type 'wye' <br />adapt adaptors at the mop sink faucet for use with chemical dispensing systems is prohibited. <br />Additionally chemical dispensers cannot be connected to the mop sink faucet. The chemical <br />dispenser must have a separate water connection. A'sidekick' adaptor at the mop sink faucet is <br />acc�ptable. � <br />I <br />