Laserfiche WebLink
March 2, 200G <br />/ PUBLIC SERV/CES DEPARTMENT <br />Mc Nam Do of I Icmy's Donut, c/o l�racc �C Associa�cs, [nc. <br />I GOS Sammamish Road # 107 <br />Issaquah, �VA 93201 <br />ProjccL• Iicnry's Dnnut <br />Job Address: 7415 [iardcson Road /iD <br />Pian Rcvicw No: C0G03-025 <br />Dcar Mr. Do, <br />In responsc to your application fiir construction pcnnil, your plans havc bccn cx�mincd and yau arc advised <br />that a pern�it cannot bc issued until lhc following issucs arc resolvcd. Thcsc conuncnts address building <br />issucs only. Additional revisions or additions may Uc rcquircd by othcr dcparUncnts (such as Utilitics, <br />Planning or I�irc). All rofcrcnccs rcfcr to thc 2003 Intcrnationai Quilding Codc (13C), or thc 2003 <br />Intcrnational Mcchanical Codc (IMC), hoth as amendcd by thc Statc of Wasliington, unicss noted othcnvisc. <br />In ordcr for thc processing of yaur application to continuc, it will bc neccssary to providc thc 13uilding <br />Divisim� �rith h��o complMc sets of dra�vings reflccting thc corrections requcsted. <br />Constructiau <br />1. Indicatc the ma�imum vertical dinunsion Uehvecn the 1'ype I hood and thc top of both appliunccs, <br />which sl�ould not excced 4(ect, per IMC Sections 507.11 and 507.12. Indicatc the exhaust disaharge <br />as a minimum of AO inchcs abovc thc roof, per IMC 50G.3.12.1, wilh a drain ouQet to an app:ovcd <br />grcase rescrvoir, per Section 50G.5.2. <br />2. 7'hc 22 gaugc stainless stccl wall 1lashing with firc-ratcd insulation should c�tend 18" above the <br />Typc I hood per IMC Scction 507.9. <br />3. An additionat vertical grab bar is rcquired in the toilet compartment, per ANSI Al 17.1-2003, Seclion <br />604.S.L [f a closcr is provided on lhe door, an additional l2 inch dearanee is rcquircd on the latch <br />side of the front approach, per ANSI Al 17.1-2003, Scetion 404.23.1. Rcferencc shcct A7.1. <br />4. The cashier counter height should not excecd 3G inches far a minimum 30 inchcs in length, per <br />ANSI AI 17.1-2003, Scction 9043.2. If fixcd scating is providcd, a mininwm 5"/o oCall seating, but <br />not less than onc, shauld bc acccssiUlc for a whccichair, per IBC Scction i 109.1 I. <br />Upon suUmission of thc rcviscd dra���ings, your application will bc givcn priorily and �>tan revicw will bcgin. <br />All rcquired submittals must be of sufficicnt dctail and infonnation to ensurc that the praposed structurc will <br />Ue constn�cted in compliance with all adapted codes. You can rcach me direcUy at 425-257-5813. <br />Sinccrcly, � <br />���, , , �7 <br />'!/ � \ r" �t� \/ <br />/ . <br />M4g �-L [ Ialey � � , <br />A�sociatc L'nginecr <br />IlY OF EVERETT • 3200 Cedar Street • Everett, 1VA 98207 •(425) 257-8800 • Fax (425) 257-8856 <br />S:N1linlcy\WoN�C��G03-02N 7415 Ilanicson Rmd-U.Aoc <br />