Laserfiche WebLink
- <br />� <br />MATT BABCOt,.0 <br />10748 DAYTON AVE. N, SEATTLE, WA 9ts133 —(2G6) 363-4950 <br />M BA 6COC K@COM C A ST.NET <br />of the pl�ns on shects A2 anJ A3, and �hc illuminatcd exit signs ha�e bcen not�d as "existing to <br />remain, not code required." <br />2. Minimum door Icaf siu <br />„ The door bMwecn the kitchen and ihe dining room has been changed from a doublc-acting door <br />with (2) I S-inch leavcs to a doublcacting door with a singlc 36" la1f, in accordance with IBC <br />1008.1.1. This changc is refl�� ted on thc plans on shcets A2 and A3 and on the door schedule, <br />sheet A2 (dc�or rype #5). <br />3. Toilet room finishcs <br />V� Notes havc bcen added to shcet A2 rcquiring floor and wall finishcs at ihe ncw toilet room to <br />comply with IDC I210.1 and I210.2. <br />4. Toilet room clearances <br />� A detail plan has bcen nddai to sheet A2 showing thc �.quired clearance betwcen the sink and <br />the wall that contains the toilet paper dispcnsor, thc required dcarance bctween the ccnterline of <br />the sink and the adjaccnt wall, and the roquired ::0" a 48" clear floar space. As we discussed. <br />clearances at the toilct room door aro addressed by legend bug # 16 on sheet A2, which refers to <br />dMail 5/A3. <br />5. Piva oven <br />As we discusscd, I have attached a cut shcet for the pirza oven, Wisco Modcl 425. This is n <br />small counlertop unit that plugs into a 120V wall outlet and draws less powcr than a toastcc It <br />is out understanding that no typc of ventilation hood is required for this picce of equipment. <br />� � 6. Tvoeofconstruction <br />Thc typc of construction was crconrnusly listcd as 11-D undcr "Building Code Infortnation" on <br />shcct AI. This has bcen changed to V-D per your cmail, attached. Thc wall type schedule, <br />shect A2, has bcen reviscd to allow wood framing at new intcrior partition walls, in accordance <br />with conslruction type V-D. - �, <br />� �FZ. �-1V�itl�:r N;_u„-� CJ� i "irc'd� �i�IS'�;�ic <br />We havc procceded with corrections to the drawings before recciving your o�cial corcection Ietter <br />in order to expcdite the permit proc�ss. 1 understand Gom our phonc conversalion that you expcct <br />that the forthcoming corrcetion Ietter will not include any major or complcx corcection items beyond <br />those addressed above, and that you have ofTcred to makc redlinc corrcctions for any additional <br />corrcction items containcd in the Icttcr. Thank you for helping us with this -- wc appreciatc all your <br />efforts to expcditc our building pennit. <br />Please call if you havc any questions or commcnts regarding any of thc above. <br />Sincercly, . ----1 <br />; ��\ <br />r , <br />\� <br />Matt Uabcock <br />�agr�6TG / '� ({ � <br />l ,J' <br />