My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1136 GRAND AVE A&B 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
1136
>
1136 GRAND AVE A&B 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2017 4:38:22 PM
Creation date
2/21/2017 11:14:13 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
1136
Unit
A&B
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( � <br /> April 23, 2007 <br /> Mr. Scott Andcrson <br /> L&A Job No. GA126 <br /> Page 9 <br /> 2,500 psf for footings poured on structural fill constructed on these competent basal soils. <br /> 'I'he footing bearing sc.ils should be verificd on-site by a geotechnical engineer after the <br /> footing trenches havc becn cxcavated and beforc the footings arc poured. <br /> • The minimum depth to bottom of perimeter footings below adjacenl final exterior grade <br /> should bc no Iess than I S inches. 'Che minimum depth to bottom of the interior footings <br /> bclow top of floor slab should bc no Icss than 12 inches. <br /> • The minimum width should bc no Icss than 16 inchcs for continuous footings, and no Icss <br /> than 24 inches f'or individuul footings, exccpt those footings supporting light-weight <br /> porches and wood deck. <br /> A one-third increase in the abovc rccommended allowable soil bearing pressure may bc used <br /> �vhen considering short-term, transitory,wind or seismic loads. Por footing foundations designed <br /> and consweted per recommendations above, we estimate that the maximum total post- <br /> construction settlement of the duplcx building should be 3/4 inch ot Icss and the differential <br /> settlement across building��idth should be 1/2 inch or Icss. <br /> Lateral loads on buildings can bc resisled by the friction force betwecn the foundations and the <br /> subgrade soils or the passive earth pressure acting on the below-grade portion of the foundations. <br /> �or the lattcr, thc foundations must be poured "ncat" against undisturbcd soils or backfilled wilh <br /> a clean, Gce-draining, compacted structural fill. We recommend that an equivalent lluid density <br /> (GPD) of 350 pcf (pounds per cubic fooQ for lhe passivic earth pressure be used for lateral <br /> resistance. The above passive pressure assumes thttt the backfill is level or inclines upwazd <br /> behind thc foundations for a horizontal distance at Ieast hvice the depth of thc foundations below <br /> final grade. A coefficicnt of friction of 0.60 behveen thc foundations and the subgrade soils may <br /> be uscd. 7'hese am unfactored values, and a proper factor of safety should be used in calculating <br /> thc resisting fi�rccs aguinsi latcral loads on thc buildings. <br /> L1U & ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.