Laserfiche WebLink
� <br />L'J <br />� <br />✓��. The construction at the interior stairs on all units should be shown in section, and <br />indude a cross section indicating a wall or guard on the main plan for all units. IBC <br />section 1013 and R312.1 <br />vio. Guard details and dimensions should be shown on the drawings where the elevation <br />difference exceeds 30" at the main level porch for Units C and D. IBC section 1013 <br />�t t. Please remove the plumbing fixture table R307 diagram from the drawings, since it has <br />not been adopted by the State of Washington. The following information should be <br />shown on the drawings for fixture clearances. UPC 402.5. <br />c. 15 clear from fixtures to wall or to an obstruction. <br />b. The finished height of the nonabsorbent wall surfaces to 70 inches above the <br />drain inlet in the shower should be shown on the drwings. IBC 1210.2.4 <br />c. Waterproof joints be[ween the shower assembly and the wall should be shown <br />on Uni:s C and D. IBC 1210.2.4 <br />d. The drawing of the shower does not appear to have adequate dearance belween <br />the toilet and the door-field verify. <br />✓tz Please remove the garage dwelling separetion R302.6 table from the drawings, since it <br />is not applicable to a public garage. A one hour fire resistance rated separation between <br />the garage and lhe residences above should be shown and detailed on the drawings, to <br />reference a one hour tested assembly with IIC 50. IBC 406.4, IBC 508.1, Table 508.4, <br />IBC 1207.3 <br />a. Clear height in the garage should be shown in section as 7 feet. IBC 406.4.1 <br />b. Floor surfaces should be sloped towards a drain or the vehicle access doonvay. <br />IBC 406.4.5 <br />13. Please cross-reference the sections of walls separating units on the plans. <br />� 19. Please removc reference to area separation wa0s on shcet 7 <br />d. Roof trusses should be shown offset at bearing wall betvacen units, typical. <br />c. ihe rated wall separating unifs C and D is required to have 50 STC sound, not <br />shown on thc drawings. Please submit a revised detaiL II3C 1207.2 <br />f. Please remove rated assernblics thaf are not rcferenced on lhis projed: GA File <br />number 3360, 387_0. <br />g. A lwo hour fire separation wali is referenced on Units C and D in thc garagc. <br />Please verify. <br />h. Rating should be shown in a dclail continuously to the underside of the roof <br />shcathiny, rnainlaininy Lhe ratirzg through and above Ihc roo( trusses. R302.3 <br />I6C 708A <br />�]5. Building envelope requirements for compliance with the energy code should be shown <br />on the drawings. WSf_C Table R�02.1.1 <br />� <br />�,3� t <br />