Laserfiche WebLink
c <br />c> <br />6. The 90-minute doors within the ASW at the first floor should be keyed to tLe <br />doorschedule. Secdon 504.6.2 <br />Wall Section 4/A-13 should note that there will be no openings in the roof within <br />5 feet on either side of the ASW. Currendy, the elevator pressurizadon Ean and <br />fireplace exhaust vendchimney (from wit6in the fourth floor lounge) may be <br />within 5 feet. Section 504.6.4 <br />8. A detail of the GWB plenum for use in attic venting should be provided. Detail <br />8/A-16 is not specific to the plenum. Section 1505.3 <br />Exiting <br />i: The first floor stair enclosura entry doors should be labeled on the plans. <br />2: One stair should continue to the roof surface as the slope is not grearer than 4:12. <br />Section 10033.3.11 <br />3. Access to an attic space over the stair enclosure should be from within the stair <br />enclosure as the adjoining attic is not a normally occupied space. Section <br />1005.3.3.5 <br />The elevator should be provided with a lobby at each floor. Section 1004.3.4.5 <br />Conidor doors 425, 427, 429 & 430 have been misarranged on the door <br />schedule. <br />6. The conidor doors through the ASW should have exit signs on both sides of the <br />wall. Section 1003.2.8.2 <br />7. The glazed openings into the corridor from the exercise, reception and o�ce <br />rooms should be specified as 45-minute gtazing. Section 10043.43.2 <br />Accessibility <br />1. The van accessible parking spaces should be show as having an 8' wide access <br />aisle adjacent to the space. Section 1107.2.4 <br />2: � The details and requirements for areas of evacuation assistance should be <br />provided (telephone, fire protection, signs, etc.). Section 1104 <br />STRUCTURAL <br />General <br />The geotechnical report should be provided. <br />P.T. Tendon and mild reinforcement layouts are requireu prior to the issuance of <br />a building permit. <br />OEPIIPCILEFJM EADO N51I I <br />