My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1915 RAINIER AVE 2016-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
1915
>
1915 RAINIER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2017 9:24:40 PM
Creation date
2/24/2017 5:07:19 PM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
1915
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
InsoectionTvpe Date Result Remarks <br />1915 RAINIER AVE <br />Permit: C0710-001 Status: FINALED Issued: 11/30/07 Finaled:3/19/10 <br />Description: TWO STORY ADDITION <br />NoteslConditions: <br />Framing 4/14/08 Corr Reqd See notes <br />Corrections: <br />1. Strap cut plates at garagelshop wall 1 1l2" x 24" framing straps <br />2. Seal piate penetrations <br />3. Seal exterior plate lines <br />4. Hole too big for piumbing drain- need engineering <br />5. Mechanical not signed off <br />6. Firestop furred wall at stairs and landing <br />7. Install A-35's per Shear wall schedule <br />8. Truss drawings and approved plans not on site <br />Consultation 4l15/OB <none> <br />Explained corrections with contractor <br />Framing <br />4/18/08 Approval <br />MechRoughln 4/16/08 <br />Mech rough in approved as noted: <br />InsulBldg <br />DrywailNailing <br />DrywallNaiiing <br />4/23/08 <br />To Records: <br />re: Framing Corrections <br />Note:strap duct cut out at west wall <br />Approval See notes <br />Compiete exhaust fan in downstairs bathroom. <br />Corr Reqd R-38 required in ceiiing <br />6/11/08 PartialApproval <br />10/16/08 Approval <br />OK-EXCEPT garage <br />Garage <br />StatusReview 5/18/09 See notes <br />Status review: Last inspection was 10-16-08. Project appears done. Violation at 2nd floor deck. <br />Send letter requesting Finals for C0710-001, E0712-027, PW0770-017 <br />Letter S122/09 Reminder need finals <br />Final Mech 6/4/09 Approval <br />Final Plbg <br />6l4/09 Approval <br />Final Bldg 6/4/09 Corr Reqd See notes <br />Corrections: <br />1. Stairs to garage not code--both steps should be 6" high <br />2. Cail for Electrical Final <br />Final PW 6/�'09 Corr Reqd No answer at door-see notes <br />Correction: <br />1. Appears that there is a �ew ABS Clean out outside of new addition- need to verify if this is sanitary <br />sewer. If this is sanitary sewer it is NOT the correct type of pipe- should be gasketed sewer pipe <br />Final Bldg 1/28/10 Corr Reqd See notes <br />Corrections: <br />1. Correct stair risers <br />2. Electrical Final <br />3. Public Works Final <br />Final Bldg <br />Mark Final" <br />3/19/10 Approval <br />3119/10 Approval <br />Note: Subject to Public Works approval <br />S:\MMcleod\Crystal\InspectionRecords.rpt 1/24/2011 _ ^1 <br />�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.