My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2720 RAINIER AVE 2016-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
2720
>
2720 RAINIER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2017 7:16:25 AM
Creation date
2/24/2017 5:45:12 PM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
2720
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' � � � <br />Ltr. D. Klappenbach (B0202-026) <br />Apri18,2002 <br />Page 2 <br />'. An assumed property line should be shown between the maintenance and <br />operations buildings. This plan review assumes that the line will be located at the <br />exterior wall of the maintenance building (most advantages location). Section <br />5033 & Table 5-A <br />3. Sprinkler note: The ceiling creates a void space in the roof. As plywood decking <br />is used, the space is not entirely noncombustible and sprinklering the roof/ceiling <br />void will result per NFPA 13. <br />4. The quantity and condition of hazardous materials should be submitted in a report <br />which is strucmred to follow Tables 3-D and 3-E. Control areas should be noted <br />on the plans as well as any'specified containment per UFC Article 79. Section <br />307.1.6 <br />5. Equipment or machinery that generates a glow, spark or tlame capable of igniting <br />Flammable vapors shall be installed with sources of igoition at least 18 inches <br />above the floor. Section 3Q7.A <br />6. Toilet room floors should have a smooth, hard nonabsorbent surface such as <br />concrete, ceramic tile or other approved material that extends upward onto the <br />walls at least 5 inches. Section 807.1.1 <br />i <br />Construction <br />1. A 30" minimum height parapet should be shawn on the northern exterior wall <br />(depending on the location cf the assumed property line). Section 709.4.1 <br />2. The canopy creates floor area per Section 2U7 and therefore Section 705 dces not <br />apply. The folloµ ing comments result: <br />a. The canopy is a roof/ceiling assembly that should be of minimum one- <br />hour construction. Section 604.1 <br />b. Depending on the location of the assumed property line between the two <br />buildings, an additional wall may need to be built if opening protection is <br />required at the North end of the canopy. Section 503.2.1 <br />3. Listings should be shown on the plans for the fire-resistive Floodceilings (with <br />T'JI's) and roof/ceilings. Section 703.1 <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.