My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 RAINIER AVE B 2016-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
1130
>
1130 RAINIER AVE B 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2017 12:03:51 PM
Creation date
2/24/2017 6:50:55 PM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
1130
Unit
B
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r� .I <br />� p�L�� w�%�KS <br />"�� <br />f�larch 3, 2014 <br />Ms. April House <br />Ventron LLC <br />3720 Thistle St <br />Seattle, WA 98118 <br />Project: Multi-family housing units <br />Job Address: 1130 Rainier Ave, Building E3 <br />Plan Review: Mi30�-�f9— <br />n1 iyU2-c>� q � <br />RE: Corrections Letter <br />\ J <br />-- — ; <br />Sent vin e-mail � <br />s/3 / ��_-1 <br />Dear Ms. House, <br />The plans have been examined, and the drawings submitted are incomplete, as noted below. <br />Some of the cemments are general in nature, since additional details are required. Plan review <br />will commence when r,vo sets of dra�vings are submitted to resolve the following issues. Please <br />provide a response Ietter, v;hich sho�vs �:�here each item in t'r�is correction Ietter is addressed on <br />the plan sec. <br />General <br />1. Please submit standard sizc sheets for plan re��iew, instead of half-size. <br />Co��struction <br />1. Compliance with naturai ventilar.ion, mechanical ventilation, and exhaust requirements <br />should be identified on the mechanical drawinys with notes, so lhat someone else could <br />construct them. <br />a. The exhaust fans and ducts to the exterior and outside air should be shown on <br />the drawings, per IBC section 1203.1 and IMC table 403.3 ventilation rates. <br />i. Toilets require 25 CFM identifying continuous or 50 CFM intermittent <br />operations, identifying continuous or intermittent operations, dra�ving <br />outside air per IMC 403.8.6.1. Exhaust cannot be recirculated. <br />ii. Kitchens require 25 CFM continuous ar 100 CFM intermittent, identifyinq <br />continuous or intermittent operetions, drawing outside air per IMC <br />� <br />iv <br />403.8.6.1. Exhaust cannot be recirculated. <br />Living areas require compliance with IMC table 403.8.1 continuous ��� <br />403.58.5.1 intermittent, based on occupant loads per ]MC table 4D3.',. <br />Whole huuse ventilation system requirements and supply of outside air <br />(not from corridor) should be shown on the drawing to comply with IMC <br />403.8.3 and 403.8.6.1. _:�..� <br />1, Trickle vents, if provided on the windows, should be Shown in <br />detail on the drawincs with calculations for the required openings. <br />Whole house ventilation system should be identified as continuous or <br />intermittent, per IMC 403.8.2; with the controls shown on the drawings. <br />
The URL can be used to link to this page
Your browser does not support the video tag.