2. Previous comment: The accessible route should be shown in its entirery on thc <br />architectural site plan Jrawings, with details referenced to the plans, for the pedestrian <br />and vehicular access site points to the accessible building entrances served, per IBC <br />section 1104.1. <br />a. Details should be referenced on the new architectural site plan, sheet A1.0. <br />a) The location of the van accessible signage should be shown on the drawings, per <br />IBC section 3411.4.2 (3). <br />a. Signage shoivn on sheet AI.O is not the corred h,eight fo� a van accessible <br />parking space, perA117.1-2003 section 502.7. <br />b) Ramps should be shown with level landings, at the top and bottom of stanriard <br />ramps, per ICC A117.1-2003 section 405.7, or at curb remps per ICC A117.1-2003 <br />section 406. <br />a. The detail for the ramp on Sheet A1.0 �efers to the plan for length, but the <br />site plan does not indicate the length ramps, to indude curb ramps. <br />c) Ramp landings should be dimensioned on the drewings to meet the minimum width <br />requirements for tums, per ICC A117.1-2003 section 405.7, when they are part of <br />the accessible route, per IBC section 1104.2, or the accessible means of eg�ess, per <br />IBC section 1007.2. <br />a. Dimrnsions not sho�vn on plans. <br />d) Within thc propercy line, remp, sidewalk, and stair widths should be shown on the <br />drawing to be a minimum of 44 inches, per IBC section 1101.2.2, when they are part <br />of the accessible route, per 18C section 1104.2. <br />a. Dimensrons not shown on plans. <br />e) Within the property line, ramp and stainvay handrail extensions should be shown on <br />the drawings for the accessible route, per IBC section 1012.6, when they are part of <br />the accessible route, per IBC section 1104.2. <br />a. An aaessib/e route is desrgnated to Burlding A with a 4.8°o ramp and 8.6" <br />rise wifhout handreils, per ICC A117.1-2003 section 905.8. <br />b. Edge protection should be shoivn on the drewings per ICC A117.1-?003 <br />section 905.9. <br />3. P�ev_ious comment.• Please provide a section through the threshold connecling the <br />euilding B lobby with the exterior landi�g. A floor or landin9 should be shown at tfie <br />same elevation on either side of the door, per I[3C section 1008.1.5, not to exceed the <br />threshold requirements of ICC A117.1-2003 sections 303.2 and 303.3. <br />a. At minimum, [he plans for Type A, Type 8 units and the communiry room slrou/d <br />�eference detail 1Z/A8.2 at the doo� entry, typical. <br />�}. The gate at chain link fences should have a smooth surface (within 10 inches of the <br />grede, measured vertically) on the push side of the gate, extending the full vaidth of the <br />gate, shown on the drawings, per [CC A117.1-?_003 section 404.2.9. <br />Deferred Permits Requiring Drawings <br />1. Nlechanical, sign, and suppression permits should be submitted as separate permit <br />applications. <br />%// <br />