' + � <br />2. P�evious comment.• Please indicate a posted occupancy sign on the dra�ti�ings for the <br />community room. The posted occupancy sign shouid be for the highest load <br />anticipated for either an assembly use (if less than 49` or an assembly occupancy (if <br />greater than 49), per IBC t� ble 1004.1.1. <br />a. Tl�e posted occupancy sign fo� the comrnunity room requi�es calculatrons on tl�e <br />d�aavings, refe�encing the occupant load for the fundion of the space, per IBC <br />table 1009.1.1, and the posted occupancy sign referenced to the plans. <br />b. Tlre occupant load of 100, sho�a�n on detail 1/A9.1, a exceeds [he highest <br />capacity for standing room only at 5 sf per occupant net Fo� fhe area of the <br />community room, per IBC ta6/e 1009.1. i. <br />i. The plans for the community room should have additronal drmensiens to <br />locate tl�e ivalls perpendicular to column lines 10-12. <br />ii. The target to the plan detail 8/A5.1 is not a plan detail, but an e%vation. <br />The area of the community �oom cannot be calculated with tlie <br />information p�ovided on the plans. <br />Egress <br />i. Previous comment: An architecturel site plan is requirec for review, for compliance with <br />the building and fire codes, per IBC 1101.2, and IFC Chapter 5. <br />a. Please indicate all the improvements for accessible design and the accessible <br />route, in their entirety on lhe architecturel site plan drawings, specificaliy within <br />the property lines. <br />i. Additional defails targeted to tl�e site plan, dimensions shown on the site <br />plan, and enougl� information contarned on sheet A1.0 are requrred so <br />that someone else could build it f�om this draiving �vithout furthe� <br />consultafion. <br />1. The const�uction of the acrossible means of egress from Type A <br />units, Type B units and the community room to the publrc ivay <br />sllould be shown in their entirety on tl�e architectural site plvn. <br />1. Note: the use of lvrge arroi-v to sho�v fhe direction of travel are <br />obscuring the construc[ion ot Ihe e%ments that n�ill be issued for <br />building permit. <br />2. Previous commcnl: An illuminated eait sign should be shor; n on the drawings �•ahere <br />more than lwo exils are required, per 18C section 1011.1 for the sliared pvtio. <br />3. Previous comment: Landings are required on both sides of egress doors or gates, per <br />IBC sections 1008.1.5 and 1008.1.G. <br />a. Landrngs at the pedestrian gates should be shoivn on the drawings. <br />Accessibility <br />1. P�evious comment: If a higher level of compliance is selected by the architect, it will be <br />reviewed for compliance with adopted state laws for compliance with that seleclion. <br />Federal ADA regulations and sfanda�ds may be more �estrictive. The Americans with <br />Disabilities Act is enforced by the Department of Justice. <br />a. P,zase remove all drawing references to 'ADA' wifhin the property lines of the <br />project, and replace ivith tlre term accessible; per IBC sectron 1102.1. <br />