Laserfiche WebLink
, 2412 Oakes� • � D f'' � I <br /> � f� <br /> Install new duplex receptacle in upstairs hall, two new <br /> duplex receptacles in kitchen as shown, (and make <br /> existing duplex receptacle on west wall of kitchen mount <br /> vertically) , install two new duplex receptacles in <br /> center bedroom downstairs (one on north and one on east <br /> walls) and replace single receptacle on west wall. <br /> Install one. new duplex receptacle on west wall by stairs <br /> in living room. <br /> � <br /> $ .3 , 00 <br /> , <br /> ALTERNATE (This item may be substituted in the contract for <br /> Item � of the Specifications. Do not include tax in the bid <br /> foc this item. ) — <br /> 1. Tear off existing c.a.b. skirting around foundation <br /> complete. Sring house to reasonable level, taking care <br /> to provide sufficient compressive resistance at <br /> southeast and southwest corners. Replace any posts that <br /> ar.e damaged by infestation cr are too short. Replace <br /> any rotted backing members. Provide proper clearance <br /> between wood and soil to code. Install new pressure <br /> treated T1-11 plywood, 1/2". Provide necessary <br /> _� foundation ventinq to code. Install new post on new 12" <br /> x 12" pier block under point load from post from <br /> southeast corner of middle landing of stairs. <br /> s �+ �.Ao0 — <br /> —� <br /> , <br />