My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2703 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
2703
>
2703 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 11:27:44 PM
Creation date
2/24/2017 11:27:28 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
2703
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r . <br /> . _ , � <br /> , . l <br /> ����� <br /> 16. Exterior (court) walls within ....................f�t ot 31: Woo sum�board ceii ngseshoWd bc out Icss tl an <br /> lines should bc of...............:hour canstruction. ZY�ch nominal thickness. Section 4704 (L). . <br /> Section .................... 03 (a)• [Section 4703 (b) (or wall ;tripping.l <br /> ( ]7. Openinss in exterior(court) walis within ............ 32. Final partition layouts and Jetails sho�ld bc sub• , <br /> � leet of propeAy lines should he prolected with ��itted prior to installation to justity compli• <br /> � three�lourths•hour tire assemhlies. Section � ance with occupancy, tire�resistive, structural, <br /> , ,,,,,,,,,,,,,,,,,,, 03 (b). ; and ezit requirements. <br /> 18. Usable space under the tirst iloor except in 33� Justilyin�test data in conformance with Section <br /> Group 1 (J).Ocn�pancies should be enclosed lp� or an ICBO research recommendalion is <br /> s required in Section 1703. required for ....................................................... <br /> 19. Fire•resistive construction tor structural frame <br /> i <br /> elements in the exterior walls shovid comply 34. Rooms in wl�ich rubbish (linen) chutes terminate <br /> wilh Foolnote No. 1 of Table No. 17•A and should bc separaled from the remainder ol thc <br /> ' Seclion ................. .... See Section 1702 tor building with a one•hour occupancy separation. <br /> clariifcation. Section 1706 (c). <br /> N1, Building Paper should be applied to ezterior 35. ��ot�bes locatedb n�srequ'��red�exi[hcorr dors uor <br /> walls as specified in Section 1707 (a). stairways. Section 1706 (c). <br /> ' 21. Enclosures for tlour openings should comply SPECIAL OCCUPANCY REQUIREMENTS <br /> with Table No. 17•A, Section 1706. Details <br /> should cicarly indicate this. <br /> 22. Structural members carrying masonry or con• ........... . ........ .......... .................... ........ ' <br /> trete walls in buiidings over one story m height ••• ' <br /> .. .. . . .. <br /> should be protected with minimum one�hour Group B <br /> 1ire protection. Section 1708. <br /> .................---.................................................•-- <br /> .._,_.,. 36. 83 Occupancies shouid be of one•hour ire� <br /> ............................. � resislive construction if IocateA in a haseme� t <br /> ' . .......................................................................... . or above.lhe first stoiy. Sect:on 702 (b). <br /> 23. Nonabsorbent finish and backin�tor toilet room ' 37, g-2 Occupancies with an occuG�nt load ot iC00 � <br /> walls and tloor should conform with Section or more should be in Type I, II, III one�hour, III <br /> 1711 (a'. Heavy Tim6er or IV one�hour buiidings. Tlie <br /> assembly room should not be in a basement <br /> - 24. Shower stail walls sliould be tinished with a i( it conlains tliis high occupant load. Section <br /> hard, nonabsorhent suAace to a height of 6 � 702 (b). <br /> feet. Section 1711 (b). <br /> 1� 25. Doors and panels of shower anA 6athtub en- 38.- The main entra�.ce should tront directiy upon or <br /> have'a 20�foo: wide access to a public way .l <br /> \. closure shovid compiy with Section 1711 (e) Ieast 20 teet in w:dth. :�ection 703. <br /> to (g)• <br /> � _.. inches in 39. Ligh[and ventilalion should comply with Section <br /> 26. Parapet walls not less than ............ 705. _ . <br /> . I heiRh� are required. Section 1709. . <br /> � � 27. Eave overhangs and similar architecWrat pro• 40. A One•Huur Fire•Resistive Occuvancy Separatioo <br /> ' jedions shouid compi wilh Sedion 1710. is requirec! belween the boiler or ceniral hcat• <br /> � ing piant and the reSt of the building. Scction <br /> Y <br /> .........."'....................... � 708. <br /> .............................................. <br /> """"'"""��'������������ 41. Exterior openings tor rooms containing a boiler � <br /> or central he3iing plant sho�ld be protected <br /> ' pg. Projections beyond the exterior wall should con• witli three�tourths•hou. tiraresistive assemhlies <br /> lorm�wilh the ieast restriclive of the follo�vinG� that are iixed, automatic, or self�closing if lo� <br /> (a) A point one�tliird llie distance to the proper• �ated bclow openings in znothcr story or if less � <br /> ty line from an ezlcrior wall. Section 504 than 10 tcet trom other doors or windows in <br /> � (b). the samc building.Section 706. <br /> (b) A point one-third the distance irom an as� <br /> sumed vertical plane localed where fire• - . . <br /> resistive protection of openin�s is tiret re• Group C . <br /> quired due to location of property. Section <br /> � ' . 504 (b). 42.� Atmospheric separations should eomply with <br /> ......................... ........................................ Section 802 (b). <br /> .....-.- : . <br /> ..........................................Y. <br /> """"'�����'���������� ' 43. U:.� of rooms should be clarificd. Notc th�t <br /> - rooms in Divisions 1 and 2 Oceupaoeics used <br /> 29." Envelope ceilings should satisf tl�e following for day care purPoses and rooms used for <br /> eonditions [Section A3C`� (b) 6.1: kinderCanen, lirst, or second �mde pupils and <br /> �(a) ShoWd not be used lo p�o��de lire prolec Division 3 O:cupancies cannut be located <br /> tion bcain nnd Cirdcrs supportin�more ihan e�pve the tirst story. Setlion t�02 (d. <br /> onc Iloor. <br /> (b) Cohunns should be individually fire pro� qq, Special hazard roo:ns SIwU�A bc separated trom <br /> lected.� � olhcr porlions ul thc buildin� by not Icss Wan <br /> (e) Duct and ouUet openinGs are limited to 100 a Onrllour firrResistrve Occup�ncy separa• <br /> square inches in each ]00 squire Iccl of tion. Sedion G02 (d1• <br /> eeiling area and should be protected with . <br /> ( ApprovCd 11fC [IdO1P��t� AB. OOC rcquired cad shoulA (mn! directly upon. or <br /> (d) Eleetrical out�et bores shoulJ be of steel have a :'.O�loot uide aecess �o, a I�ublic w.Y at <br /> � and nol grcatcr lhan 1G square inches m icast 20 tcet in wid�h. Seclion 803 (o). <br /> arca. qg. S,nilary fieililics shou�A hc proeidcd in aceord� <br /> 30. Gypsum board ccilinCs in tonl4nction with firc� _ ance wilb Sec1��n ���� - <br /> resislivc assemblies should bc supPortod nt <br /> inlervals nol ezceedin 1G inche,. Ilem 27. 47. I i;;ht und •ienlilalion should wmply with Seclion <br /> � eos. <br /> Tablc No. A3�C. - <br />
The URL can be used to link to this page
Your browser does not support the video tag.