My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2703 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
2703
>
2703 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2017 11:27:44 PM
Creation date
2/24/2017 11:27:28 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
2703
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • - �- � . . <br /> - . . , � , , <br /> GENERAL PLAN CORRECTION LIST <br /> � • . Based on 1973 Edition ol lhc Unitorm Building Code <br /> � , <br /> , Sr 10 M , � , � �tL a 4- <br /> Ownef......:.....:.l.S�..4s....1.^.�.!-�.:(:l..�tsA?P...�A� Plan Ch'ec!<No.7.b.:...3..,._..Valuation ........................... <br /> Job Address ...Z.���....n��k;:.�..................•••......._ Use..c:.�FLs�S.-•_�,!�!�a�z!>:�a.(L:!..........._........... . <br /> Date _.....�ti.P..�:...lk.,•-•.�.4.:1.b•••••-••• •••...... TYPeof Occupancy <br /> •• •••• - <br /> - ' <br /> 1:1...-_�,�..�...5,.-.�-a�..�...:.P..�.�..Jn!:.4�.� Construction ..T�.c..t.Nf�;Classification..i�-�..._..... <br /> Total h�lowable Floor Area ....L:��:�..4.R............ Sq. Ft. Fire Zone No. ......1.............Stories 1....�....Kn��c�f^!7 <br /> Basisforincrease � Floor Area: <br /> =---••-••._..................•••••-.................................._......... Fioor(PAax.) .....�.,-1.:;.Q................a:._��..:.......... Sq. Ft. <br /> --r.._..__....••••-.........-•••-....•••...................................:. Floor(Total) .........._............,-........................_.... Sq. Ft. <br /> . ...._..... Occupant Load .F.,,..�tii.....2..s_t.....�,..................... <br /> ^-----_.._..................•••-••---............_....--••••••••••-•• 3�asS+"�._,�—� " � <br /> " COh1MENTS OR ASSUMPTIONS: - <br /> . Cortettion. checked below are to be made on plans before permit is issued. � <br /> � The np;:�val of plans and specifications does not permit the violation o(any seclion of the Buildine Code,or other City Ordinance or <br /> State Lz�H. <br /> �. • � 6ENERAL c) All openings protected Nith fire assem6lies <br /> � ' having a firc�resislive rting of one-entl�one- <br /> � 1. Va�uati.n should be b.......... � . haif (threc) hours. <br /> """"""""""""""" d) Ducts through area sepvation walls should <br /> 2.` Show job address on plans. 6e awided. It allowed,tire dampers on each <br /> . . side of the watl are requireo. Section , <br /> � - �3. Givc na�;e of peison responsible for plans. 30.102, U.B.4 Stand.rds. <br /> - � 4. Submi[fu�ly dimensoned plot plan. 30. A fireaesistive occupancy separation in wnform- <br /> . , ance with Table No. 5•B and Section 503 is <br /> 5.• Give ali dimensions on piot plan. required belween the . <br /> .. . AREII I.IMITATIONS AND GENERAL .........--.................................. (...........:hours) <br /> � � � OCCUPANCY REQL'IREMENTS . ......--'.,..............................."'. (...........:hours) . <br /> �� 6. Ground �elevations sliouid be shown at.corncrs -�-••••�•---••�•••��-�--��••��••••••••���•••• f•��•������•���ours) <br /> oi the buildiny nnd ct chanEes in ground s�ope. — <br /> The Ground elevations sliould �e taken at the 11.� Horizontal occupancy separations should Le sup� <br /> lovrest poiut behvicen 1he exlcrior wall and a poAed with a structural system Im�•ing equiva- <br /> . point 5 icet out or at the property line, if Ient firrresistive proledion. Section 503 (b). <br /> , closer.\Vhere tlie extcrior wall is parallc! to and <br /> within 5 iccl of a public sidewalk, alley, or 12. Thc Guildirg is limited to....................... storics <br /> • � � other public way. lhe C�ound clevations shoWA �•����------����� �ecl in heisht) as a Type.............. <br /> Ae the etevation of the public way.Tlie number struttum. Section 507 and Table No. 5•D. <br /> oi stories in lliis bui�iinF c�nnot be determined . ,_........�....................................: <br /> ........................ <br /> . until this dafa is furnished. ' • . <br /> ..........�............................................................. <br /> 7.� Thc total 11oor area is limited lo ........................ . <br /> squarc leet. Seclions 505 and 506. .......""_"........................................................... <br /> - ✓ 13. A room in wl�ich a water closet is located slwuid <br /> S. Unobslructed yards of .................... feet should <br /> be maintained on . ....................... sides bc sepamled imm food preparalion or storogc <br /> rooms 6y . ti�ht�filting dcor. <br /> of lhe building tor arca purposes. Section 50G. — <br /> �- ( � Pruvidc deWils ro show that .............................. TYPE OF CONSTRUCTION ' <br /> � �, �, •hour arca separation walls should comply with - <br /> � Sedion 505 (c), 14. Type V (III�N) (IV•N) 6uildin�,s orr. not permiiletl <br /> • (a) [ztend vcrticalty from the loundation to a in (vc 2onc Wo. 1. Seclion 1G0^ (a). . <br /> point 30 inches ibovc thc rooL - <br /> �� - (b) Total .:iJth ol all o,enin�s IimitcA to 25 per � 15. Hoof covcrings should be firr. �etmJanL Settion <br /> eenl of U�c wall Icn�th in thc slory imdr �� 1G03 (a) or ]%04. Dclails or specilicalinns <br /> eoasidcralion. complYiuL' wilh Section 3203 (c) irc requimd. <br /> Form 3W] <br /> ' . . Sl�ecl No. 1 of 6 Shccls • <br />
The URL can be used to link to this page
Your browser does not support the video tag.