Laserfiche WebLink
Rceommendadons: Genecal - .My sutpect aSbestos containing mataials discovcred during the <br /> demolition project that have not bern sampled, should not be disturbed undl an asses�ent of the <br /> suspect material can be made. All asbestos-containu�g mazaials thaz will be disnnbed by the <br /> demolition should be removed by a certiSed asbestos abazemait contractor, using methods as <br /> outlined in: <br /> 1. EP.4�0 CFR Pact 763, Asbesros-Containing Materials in Schools. <br /> 2. EPA 40 CFR par.61, National Emission Standards for Hazardous Emission St�ndards for <br /> Hazardous,�ir Poflutants;.4sbesros NESHAP Revision; Final Rtile <br /> 3. Deparunent of Labor and [ndustries, Asbestos,Tremolite, Antbophyllite, and Actinolite <br /> �'.�C 296-62-077 tivough 296-62-07761. <br /> 4. Depanment of Labor and Industries Safery Standazds for Asbestos Removal and <br /> Encapsularion NAC 296-GS-0O1 through 050. <br /> 5. Deparanent of Labor and Industries, Respiratorv Prorectioq WAC 296-62-071 duough <br /> 07121. <br /> 6. Depazuncnt of Labor and Industries WISHA Regonal D'uective WRD2310 Apri130, 1997 <br /> �7. All current reeulaaons of Washington Srate Departrnent of TranspoRation. <br /> 8. Puget Sound Clean Air Agenry <br /> 9. All regulations of the landfill where asbestos materials are deposited. <br /> 10. 29CFR 1926 Safery and Heaith reguladon for construcrion <br /> LF.AD <br /> Seven samples were collectcd and analyzed for the presence of total lead. <br /> • Grey interior paint <O.00i2°o <br /> • White interior paint <0.0054% <br /> • Peach colored eCterior paint 32°6 <br /> • Green exterior paint 24"�0 <br /> • Green exterior paint 0.4?°0 <br /> • Beige exterior paint 259'0 <br /> RecommendaHons: Personnel air monitoring and azea air monitoring should be perfarmed by <br /> any contractor causine disturbance of lead containing painr, to ensure the safety of the workers, <br /> and the environment. DemoGdon or disrurbance of tead containing materials should be <br /> performed in accordance with: <br /> 1. Occupational Safery R Health Administration(OSH.�); Interim Rule: 29 CFR 1926.62. <br /> Z. WAC 296-I55-176 <br /> 3. Occuparional Safery&Health Adminishation(OSHA); Interim Rule: 29CFR 1910& 1926 <br /> 4. Geuers!Occupational Hea!th Standards WAC 296-62. <br /> 5. EPA Air Qualiry Crireria for Lead. <br /> 6. PS?.PCA Air Qualiry regulations. <br /> 7. 29CFR 19I0 OSHA PEL <br /> 8. 29CFR 1926.55 Safety m�d Healch Regulations for Construction <br /> 9. 29CFR 1936 103 Respirators <br /> 10. 29CFR 19I0.1000 <br /> i l. WAC 296-62-0715 Control of Chemical Agents <br /> 12. WAC296-62-075 Air Contaminants <br />