< <br /> ., <br /> 6. Walkway connections are required as shown on the preliminary plan. <br /> • 7. City streets and alleys are co be kept clear of dirt and debris at all 6mes during <br /> wnswcdon. Dust suppression and street cleaning must occur as directed by the <br /> Public Works Inspector. <br /> � <br /> 8. As-builts of storm sewer, sanitary sewer, and water systems will be required to be <br /> submitted per Ciry Design and Construction Standards and Specificadons for <br /> Development. <br /> 9. A Performance Guarantee is re�uired for the alley improvements and the sewer <br /> main construc6on prior to any building permit being issued. <br /> 10. Any broken or damaged sidewalk shall be repaired/replaced per the Ciry Public <br /> Works Inspector. <br /> 11. A-L curb and gutter must be installed along this property's 32od street frontage. <br /> 12. Curb-ramps meeting Ciry and A.D.A. standards must be installed at the 320° <br /> street. and Oakes intersecdon. <br /> 13. For the 20 units proposed, a minimum of 20 parldng stalls is required. A <br /> minimum of 1 accessible handicapp� spact must be provided. <br /> 14. Placement and scroening of refuse disposal amas must be provided per Secdon <br /> 39.080 of the Zoning Code. Garbage receptacles, dumpsters, and recycle bins <br /> shall be provided in all muldple family, commercial, industrial and insdtutional <br /> developments and shall not be located in a required front yard setback area, or <br /> street side setback area for corner lots. Where an alley abuts a lot, the gazbage <br /> receptacles, dumpster, or recycle bin shall be located adjacent to the alley. <br /> All garbage dumpsters and recycle bins must be screened from view from the <br /> street and fmm adjacent properties. This screening may be done using dense <br /> vegetation or by placing the dumpster or recycle bin in a structural enclosure. <br /> � 15. Any rockeries or retaining walls proposed in required setback areas must be in <br /> conformance with Section 39.150 of the Zoning Code. In general, rcekeries and <br /> retaining walls cannot exceed 36" in height in required setbacks <br /> 16. Rooftop mechanical equipment, including vents, must be scre�ned per Section <br /> 39.040 of the Zoning Code. <br /> 17. Building setbacks must be minimum of 10 feEt fmnt yazd, 10 feet corner, S feet <br /> rear yard and 5 feet side yard, except that additional side setbacks ace zequired for <br /> portions of the building that exceed 35 feet high. Building height shall be a <br />