My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3216 OAKES AVE 2016-01-01 MF Import
>
Address Records
>
OAKES AVE
>
3216
>
3216 OAKES AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2017 12:47:37 AM
Creation date
2/25/2017 12:47:16 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3216
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �o ' Frank Ii. Bennett <br /> FROM ,7�ie G. Johnson ./"2� <br /> ��rE May 20 , 1975 <br /> si,��[cr <br /> �WEl�.11]Cf ZIISLJ0CL1071 ur• or [�fir�.tr t���e��r. ...:�r��N;io�. <br /> 3216 Oakes <br /> 'Phe following is a list of deficiencies of the Uniform iiousing <br /> Code, which are required to be corrected, together with :i list <br /> of additional deficiencies of the Uniform Building Code, which <br /> of�the aboverreferencedadwellinqeoncIaa d5ri1975ur inspection <br /> Uniform Housing Code <br /> 7., General <br /> la. The upper floor is inadequatle}� heated. The <br /> daelling is required to be provided with heatinq <br /> facilities capable of maintaininq a room temp- <br /> erature of 70°F at a point three feet abave the <br /> floor. Section 701 (a) . <br /> lb. The space heater appears to be ir.mproperly installed. <br /> All wiring should be concealed or protected. <br /> Section 300-4 NEC. <br /> lc. Bedrooms appear to be insufficiently ventilated as <br /> requirA � by Sectic.n �09 (d) • <br /> ld. Bedrooms are not provided with adequate emergency <br /> exiting , ecxept for the southwest bedroom, as set <br /> forth in Section 8U1. <br /> le. Adequate means of egress is not provided from <br /> balcony at southwest bedroom in compliance with <br /> Section 801. If adequate guard rails and stairs <br /> from this balcony are not provided then the door <br /> should be removed and light and ventilation in <br /> comp.liance with Section 504 and exiting in <br /> compliance Section 801 should be provided. <br /> 1�. The laundry floor indicates settling at the west <br /> e::terior wall. An adequate foundation should be <br /> provided. Section 1001 (c) . <br /> lg. The buil.ding floors are not level indiorting <br /> possible settlement or inadequate supp 4 <br /> members and foundation provided. Section 100 (c) . <br /> lii. Rodent proofing at undertloor access is missinq• <br /> Sect!-on 1001 (b) 1'l• <br /> li. Geveral support posts are in contact with dirt <br /> which coulc� `ierebaockslandtends protected�asdset <br /> on concrete p <br /> forth in the building code and six inches clear <br /> from all dir.t- Section 1001 (c) • <br /> �,j , The laundry roor� ceiling and walls are not prorected <br /> from the weatl7er as provided for in Section 1001 (h) 3. <br /> lk. In severhir_h shouldSbehreplacedrokSectionr10U1 (a) • <br /> siding <br />
The URL can be used to link to this page
Your browser does not support the video tag.