Laserfiche WebLink
Plan Check No. 91/27368 <br />Page 2 of 2 <br />6. In the one-hour occupancy separation between a Group R, Division 3 <br />(Dvelling) and H occupancy (Garage), the separation nay be limitad <br />to tha installation of materials approvad for ona-hour <br />fire-resistive construction (5/8" Type "X" GWB) on the garage side <br />and a self-closing, tight-£itting solid wood door 1 3/6 inches in <br />thiclrness vill be permitted in lieu of a one-hour fire assembly. <br />In order for the processing of your application to continue, it will be <br />necessary to provide the Building Departmant with two complete nev sets of <br />drawings raflecting the corrections requested. <br />Upon zesubmittal of the drawings, your application will be given priority <br />and plan review will reco�ence, <br />All of the above information shall be of sufficient detail and contain <br />sufficient information to ensure that the proposed structure vill be <br />constructed in compliance vith the City Building Code. <br />Sectians shall be applicable to plan submitted. <br />Sincerely, <br />Jeff Heilsan <br />Engineering Technician <br />JH:jtb/11-45 <br />